This Three Phase Power Analyzer for Transformer Testing is mainly used for troubleshoot of complex power system more quickly and accurate, and monitoring and maintenance of power quality parameters more comprehensive and systemic.
It can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
Three Phase Power Analyzer for Transformer Testing adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing;
Three Phase Power Analyzer for Transformer Testing apply to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrological department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters.
| Functions |
1.Waveform real-time display (4 channels voltage/4 channels current).
2.True RMS values of voltages and currents.
3.The DC components of voltages.
4.Peak current and voltage values.
5.Minimum and maximum half-cycle RMS current and voltage values.
6.Pharos diagram display.
7.Measurement of each harmonic up to order 50.
8.Bar charts show harmonic ratios of current and voltage of each phase.
9.Total harmonic distortion (THD).
10.Active, reactive, apparent power, by phase and cumulative.
11.Transformer K factor.
12.Power factors (PF) and displacement factors (DPF or COSΦ).
13.Short-term voltage flicker (PST).
Interface as below:

| Technical specification |
Base condition and working condition
Influence factor | Test item | Base condition | Working condition |
Environment temperature | All parameters | (23±2)°C | -10°C~ 40°C |
Relative humidity | All parameters | 40%~ 60% | <80% |
Phase-to-neutral voltage | All parameters | (100±1%)V | 1.0V~ 1000V |
Phase-to-phase voltage | True RMS phase-to-phase voltage | (200±1%)V | 1.0V~ 2000V |
Current | True RMS current | (5±1%)A | 10mA~ 1000A |
Network frequency | All parameters | 50Hz±0.1Hz | 40Hz~ 70Hz |
Phase shift | Active power and active energy | Cosφ=1 | Cosφ: 0.2~ 1.0 |
Reactive power and reactive energy | Sinφ=1 | Sinφ: 0.2~ 1.0 | |
Harmonic | All parameters | <0.1% | 0.0%~ 99% |
Voltage unbalance | All parameters | <10% | 0.0%~ 99% |
Working voltage of device | All parameters | DC9.8V±0.1V | DC9.5V~ 10.5V |
External electric field, |
All parameters |
Should be avoided | |
Test position | Measured related parameters of |
Tested wire at the center of clamp. | |
General specification
Power supply | Rechargeable lithium-ion battery packs 9.6V, backup charger. |
Battery indicator | Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute. |
Power consumption | Current consumption of normal test 490 mA, continuous working for 8 hours. |
Display mode | LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm. |
Size of clamp | 008B small sharp current clamp: 7.5mm×13mm; 040B circle current clamp: 35mm×40mm; |
Instrument dimensions | L×W×H: 240mm×170mm×68 mm. |
Number of channels | 4U/4I. |
Phase-to phase voltage | 1.0V~2000V. |
Phase-to-neutral voltage | 1.0V~1000V. |
Current | 008B current clamp: 10mA~10.0A; 040B current clamp: 0.10A~100A; 068B current clamp: 1.0A~1000A; |
Frequency | 40Hz~70Hz. |
Parameters of electricity | W, VA, Var, PF, DPF, cosφ, tanφ. |
Energy parameters | Wh, Varh, Vah. |
Harmonic | Order 0~50. |
Total harmonic distortion | Order 0~50, each phase. |
Expert mode | Yes. |
Number of Transient | 150 sets. |
Voltage flicker | Yes. |
Starting current mode | Yes, 100 seconds. |
3 phases unbalance | Yes. |
Record | 300 days(simultaneous recording 20 parameters, record one point every 5 seconds). |
Min/Max recorded value | Measurement of maximum and minimum values over a period of time. |
Alarm | 40 different types of parameter selections, 12,800 sets alarm logs. |
Peak | Yes. |
Phasor diagram display | Automatically. |
Capacity of snapshots | 60. |
Menu language | English/Chinese. |
Communication | USB. |
Automatic switching off | When an alarm campaign is initiated or a search for transients, an inrush device is not automatic switching off. |
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute. | |
Backlight function | Yes, suitable for use at night and dark place. |
Weight | Host: 1.6kg (with battery). |
008B small sharp current clamp: 170g×4; | |
040B circle current clamp: 190g×4; | |
068B circle current clamp: 510g×4; | |
300F Flexible Coil Current Sensor (with Integrator) : 330g×4; | |
Test wires and power adapter: 900g; | |
Total weight: about 9.2kg (with packaging). | |
Length of voltage test wire | 3m. |
Length of current sensor |
2m. |
Working temperature and |
-10°C~40°C; below 80%Rh. |
Storage temperature and |
-10°C~60°C; below 70%Rh. |
Input impedance | Input impedance of test voltage: 1MΩ. |
Withstand voltage | Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell. |
Insulation | Between instrument wiring and shell ≥10MΩ. |
Structure | Double insulation, with insulation vibration-proof sheath. |
Safely rules | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. |
| Service and Support |
1.Strictly factory test for Three Phase Power Analyzer for Transformer Testing
All products will be assembled and test strictly according with our product process standard. All qualified products will be issued factory release reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.
2.Support technical guidance
We also provide the training for the operators. Complete training includes the skilled operations of our equipment, maintenance and troubleshooting . it also ranges the commissioning and test of our products at site!
| Introduction |
Wuhan Goldhome Electrical Equipment Co., Ltd .(abbreviated as Goldhome Hipot ) was established in 2008, formerly known as the third production enterprise of the national inspection unit, and then through the reform and recombination, we set up the high voltage testing equipment manufacturer.
Goldhome hipot adheres to the” integrity of management, quality-based” concept, dedicated to providing high-quality products and effciency & perfection after-sales service for our all customs,struggling for the global HV power doctor!