Membership
Help
Luoyang Asian Sun Wire & Cable Co., Ltd.
Luoyang Asian Sun Wire & Cable Co., Ltd.
Features
Low Voltage Copper buliding wire for use in the internal wiring of devices or for conduit Indoor Use
THW Building Wire, H05V-U/H07V-U Copper building wire Single-conductor hook-up wires with a solid bare copper core. These insulated wires are determined for the installation to the inside of apparatus as well as for the protective laying to the lightings, in dry rooms, in production facilities, switch and distributor boards, in tubes, under and surface mounting of plasters.
THW Building Wire--H05V-K / H07V-K Copper wire types
A range of PVC single core cables for use in the internal wiring of devices or for conduit or trunking wiring. Available from 0.5mm² up to 240mm² in a various range of colours.
H07V-R stranded copper building wire 450/750 Volts
PVC-insulated conductors for fixed installations. Mainly used in power and lighting circuits, both domestic and commercial applications. They are also used in the internal wiring of appliances.
H05V2-U heat resistance solid copper building wire 300/500 V
H05V2-U is a lead free, PVC insulated, house wiring cable with one circular copper conductor. with maximum 90°C conductor temperature.
H05V2-K heat resistance flexible wire copper stranded
H05V2-K is a lead free, PVC insulated, connecting cable with one circular, multi stranded copper conductor with maximum 90°C conductor temperature.
H05Z-K/H07Z-K halogen free flexible stranded copper wire
A range of Harmonised approved low smoke halogen free single core cables for use in applications where the protection of human life and the environment is at risk from the formation of acid from fire conditions. Available from 0.5 mm² up to 95 mm² in a various range of colours.
Colors available for THW Building Wire
black, blue, brown, gray, yellow, green, white, orange, red, dark blue, green-yellow

THW Building Wire specifications
H05V-U copper building wire — 300 / 500 V PVC Insulated wire (Solid Conductor)
| Conductor cross section | minimum | Outer Ø | Weight | Maximum | Conductor | Standard |
| wall-thickness | min. - max. | approx. | current rating | DC resistant | length | |
| Air 25 ℃ | at 20°C | |||||
| mm² | mm | mm | kg / km | A | Ω/km | m /coil |
| 0.5 | 0.6 | 1,9 - 2,3 | 9 | 12 | 36 | 100 |
| 0.75 | 0.6 | 2.1 - 2.5 | 12 | 15 | 24.5 | 100 |
| 1 | 0.6 | 2.2 - 2.7 | 15 | 19 | 18.1 | 100 |
H05V2-U copper building wire 300/500 V PVC Insulated,90 °C heat-resistant
| Conductor cross section | minimum | Outer Ø | Weight | Maximum | Conductor DC resistant at 20°C | Standard |
| wall-thickness | min. - max. | approx. | current rating | length | ||
| Air 25 ℃ | ||||||
| mm² | mm | mm | kg / km | A | Ω/km | m /coil |
| 0.5 | 0.6 | 1.9 - 2.3 | 8.3 | 13 | 36 | 100 |
| 0.75 | 0.6 | 2.1 - 2.5 | 11 | 17 | 24.5 | 100 |
| 1 | 0.6 | 2.2 - 2.7 | 13.8 | 20 | 18.1 | 100 |
| 1.5 | 0.7 | 2.6 - 3.2 | 20.1 | 25 | 12.1 | 100 |
| 2.5 | 0.8 | 3.2 - 3.9 | 32 | 34 | 7.41 | 100 |
H07V-U copper building wire —450 / 750 V PVC Insulated Single core wire (Solid Conductor)
| Conductor cross section | minimum | Outer Ø | Weight | Maximum | Conductor DC resistant at 20°C | Standard |
| wall-thickness | min. - max. | approx. | current rating | length | ||
| Air 25 ℃ | ||||||
| mm² | mm | mm | kg / km | A | Ω/km | m /coil |
| 1.5 | 0.7 | 2.6 - 3.2 | 19.9 | 25 | 12.1 | 100 |
| 2.5 | 0.8 | 3.2 - 3.9 | 31.4 | 34 | 7.41 | 100 |
| 4 | 0.8 | 3.6 - 4.4 | 49 | 44.5 | 4.61 | 100 |
| 6 | 0.8 | 4.3 - 5.0 | 66 | 58 | 3.08 | 100 |
| 10 | 1 | 5.3 - 6.4 | 11.4 | 79.5 | 1.83 | 100 |