TRSB 3.3 Lightning Rod

Zhejiang THOR Electric Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Lightning Rod
Place of Origin
ZheJiang, WenZhou
TRSB 3.3 Lightning Rod

Lightning  Rod  is  used  for  protecting  the  buildings  to  avoid  lightning  strike.  Lightning rod grounding  plays  an  important  part  of  the  air  termination  network  of  a  lightning  protecttem.

Building Lightning Rod, alternate named lightning protection devices, used for protecting  the

building when raining and lightning .The  lightning  rod  installed  on  the  building  and  transfer  the electric  to  earthing  metal  to  protect  the  building . Our  lightning  rod  comply  with  UNE 21.186 NFC 17. 102 or EN 50.164/1 EN 62.305 standard . Customized lightning rod available.

 

Working Principles:

During thunderstorm conditions when the lightning down-leader is approaching ground level, an upward leader may be created by any conductive surface. In the case of a passive lightning rod, the upward leader propagates only after a long period of charge reorganization. In the case of PDC series, the initiation time of an upward leader is greatly reduced. The PDC series generates controlled magnitude and frequency pulses at the tip of the terminal during high static fields characteristic prior to a lightning discharge. This enables the creation of an upward leader from the terminal that propagates towards the downward leader coming from the thundercloud.

Part I: Protection range of direct lightning arrester Rolling ball radius(R):

Class Ⅰ lightning protection building30m(National buildings, arsenal, etc.)
Class Ⅱ lightning protection building45m (Government institutional units, etc.)
Class Ⅲ lightning protection building60m(civil buildings, etc.)
Part Ⅱ: Selection of lightning protection type

 

Type      RLightning  Rod  height (h)/ protecting  range (x)
Class Ⅰ  30m30/3015/2510/22.3
Class Ⅱ   45m45/4522.5/3810/28
Class III    60m60/6030/51.910/33
 
Part Ⅲ: Caculation of protecting range
Protecting range                X
Lightning rod height         H
Rolling ball radius              R

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Typical MAST Installation Arrangement
For Cantilevered Mast
 

 

  Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support.Incorporated in 2006, Thor Electric Co., Ltd has built everything to offer a wide range of innovative and reliable surge protection solutions and products.Thor is following the international quality system standards, is ISO 9001 certified and our technical standards are in line with GB18802.1-2011/IEC61643.1.All types and classes of our lightning and surge arresters 20KA~200KA(8/20μS) and 15KA~50KA(10/350μS) are tested and pass all the requirements based on their class.Thor has been designing new products to meet the RoHS directive since 2006. Thor’s ongoing commitment to RoHS compliance includes continuing efforts to reduce the presence of hazardous substances in the design and manufacture of a growing number of popular products.Zhejiang Thor Electric Co., Ltd is committed to meeting the requirements of the European Union’s Waste Electrical and Electronic Equipment (WEEE) directive. This directive requires producers of electrical and electronic equipment to finance the take-back for re-use or recycling of their products placed on the EU market after 2005.