VS1 vacuum circuit breakers have been designed for indoor use and air insulated switchboards.
Their switching capacity is sufficient to handle any conditions arising from switching of equipment and system components under normal operating and fault conditions, particularly short-circuits, within the parameters of their technical data. The vacuum circuit-breakers of type VB4, designed in column form, can be supplied both as individual units for fixed installation and mounted on chassis. Vacuum circuit-breakers are characterized by their simple and robust construction. They have a long life expectancy. There is no adverse effect on the vacuum, even from frequent switching of operating and short-circuit currents.
Main technical specifications
| NO. | Item | Unit | Data | |||
| 1 | Rated voltage | kV | 12 | |||
| 2 | Rated short-time power frequency withstand voltage ( 1 min) | kV | 42( phase to phase,to earth) / 48( isolating distance) | |||
| 3 | Rated lightning(1 min) impulse withstand voltage(peak) | kV | 75( phase to phase,to earth) / 85( isolating distance) | |||
| 4 | Rated frequency | Hz | 1 | |||
| 5 | Rated current | A | 630,1250 | 630, 1250, 1600, 2000, 2500, 3150 | 1250, 1600, 2000, 2500, 3150, 4000 | |
| 6 | Rated short-circuit breaking current | kA | 20 | 25 | 31. 5 | 40 |
| 7 | Rated short-time withstand current( 4s) | kA | 20 | 25 | 31. 5 | 40 |
| 8 | Rated peak withstand current | kA | 50 | 63 | 80 | 100 |
| 9 | Rated short-circuit making current | kA | 50 | 63 | 80 | 100 |
| 10 | Rated short-circuit breaking current(different directions) | kA | 17. 3 | 21. 7 | 27. 3 | 34. 6 |
| 11 | Rated operation order | open - 0.3S - close open- 180S - close open | open - 180S - close open - 180S - close open | |||
| 12 | Opening time(rated voltage) | ms | 30-60 | |||
| 13 | Closing time(rated voltage) | ms | 25-55 | |||
| 14 | Rated output power of the energy storage motor | W | 100 | |||
| 15 | Breaking times under rated short-circuit current ( E2 grade) | times | 30 | |||
| 16 | Rated voltage of energy storage motor | V | AC/ DC220 ,AC/ DC110 | |||
| 17 | Rated close operating voltage/current | V/A | AC/ DC220/ 1 ,110/ 2 | |||
| 18 | Rated open operating voltage/current | V/A | AC/ DC220/ 1 ,110/ 2 | |||
| 19 | Rated instantaneous overcurrent tripping action current | A | 5 | |||
| 20 | Rated voltage of the voltage loss trip | V | AC220,AC110 | |||
| 21 | Rated on-off current of auxiliary switch | A | 16 | |||
| 22 | Energy storage time (in rated voltage) | s | <7 | |||
| 23 | Secondary circuit (1 min) power frequency withstand voltage | V | 2000 | |||
| 24 | Main circuit resistance(without plum blossom contact) | μΩ | ≤ 45(630 ~800A) ,≤ 35(1250A) ,≤30(1600-2000A) , ≤25(2500A) ≤ 20(3150A and above) | |||
| 25 | Rated breaking current of capacitor bank ( C2 grade) | A | single fuse 800,back to back fuse 400 | |||
| 26 | Distance between contacts | mm | 9±1 | |||
| 27 | Contact stroke | mm | 3±1 | |||
| 28 | Average closing speed | m/ s | 0. 5~0. 9 | |||
| 29 | Average opening speed | m/ s | 1- 1. 7 | |||
| 30 | Three - phase contactor opening and closing simultaneity | ms | ≤1 | |||
| 31 | Contactor closing bounce time | ms | <2 | |||
| 32 | Mechanical life(M2 grade) | times | 20000 | |||
| 33 | Moving and static contactor allows accumulated wear thickness | mm | 3 | |||