Membership
Help
Zhejiang Volcano electrical technology Co., Ltd
Zhejiang Volcano electrical technology Co., Ltd
Volcano Electrical have developed and produced more than 100 types of 1.14kV-40.5kV vacuum interrupters and solid sealed poles for vacuum circuit breakers, contactors and load break switches , which are widely used in power, metallurgy, mining, petrochemical, railway, broadcasting, communication, industrial high-frequency heating and other power distribution systems, with complete product specifications and stable and reliable quality.
Equipped with advanced technical equipment and production line, the production of vacuum interrupter adopts advanced one-time sealing and discharging technology, coupled with the rapid leak detection technology of positive pressure equipment, effectively reducing the product leakage rate. The special current & voltage aging process, optimized design of vacuum tube, strict production process and quality control process ensure stable and reliable product quality and good consistency.


![]()
![]()

TD-40.5kV/2500A-31.5kA
Main technical data(TD-40.5/2500-31.5)
Rated voltage | kV | 40.5 |
Rated current | A | 2500 |
Rated frequency | Hz | 50 |
Rated short-time power frequency withstand voltage (1min) | kV | 118 |
Rated lighting impulse withstand voltage | kV | 215 |
Rated short-circuit breaking current | kA | 31.5 |
Rated short-circuit making current (peak) | kA | 80 |
Rated operations of short-circuit breaking current | times | 20 |
Rated operation sequence | O-0.3(0.5)s-CO-180s-CO | |
Rated short-time withstand current | kA | 31.5 |
Rated duration of short-circuit | s | 4 |
Mechanical endurance | times | 10000 |
Rated peak withstand current | kA | 80 |
Contact closing force due to bellows and atmosphere | N | 235±40 |
Counterforce at rated contact stroke | N | 295±30 |
Circuit resistance at lowest rated contact force | μΩ | ≤18 |
Storage life | years | 20 |
Contact erosion limit | mm | 3 |
Average opening speed | m/s | 1.7±0.3 |
Average closing speed | m/s | 1.3±0.35 |
Added contact force | N | 3200±300 |
Contact bouncing duration at closing operation | ms | ≤2 |
Contact rebound during opening operation | mm | ≤2 |
Three-pole simultaneity | ms | ≤2.0 |
