Membership
Help
Winsun Automation Instrumentation Co.Ltd.
Winsun Automation Instrumentation Co.Ltd.
WSLU Serise Vortex Flow Meter
Introduction
WSLU Series Vortex Flowmeters are volumetric flowmeters which measure gas, steam or liquid volume flow, standard volume flow or mass flow according to Karman's Vortex Street Principle, and can be used as flow transmitter in automatic control system. Vortex Street Flow is divided into three categories according to its function.
WSLU-1 remote transmission vortex flowmeter, WSLU-2 intelligent integrated display vortex flowmeter and WSLU-3 Temperature and Pressure Compensation Type.
Features
Product classification
WSLU Remote Transmission Type
The remote-transmission vortex flowmeter has the advantages of low price, high integration and compact volume. Without the need for on-site display, the detected flow signal can be transformed into the working condition pulse signal or the 4-20mA current signal can be sent out by far. The flowmeter only needs to put the calibrated coefficients of the instrument into the upper computer, so it can display the pipeline flow in real time at the upper computer end. It is especially suitable for use with secondary instruments, PLC, DCS and other computer control systems.
Medium | Air, oxygen, nitrogen, coal gas, natural gas, chemical gas,Saturated steam, superheated steam,Water, high temperature water, oil, beverage, chemical liquids etc.. |
Caliber | Flange connection:DN15~DN300 |
Accuracy | Pipe type: Class 1.0 Insertion type: Class 2.5 |
Range ratio | 1:10~1:20 |
Flow range | 0.5~10m/s |
Medium temperature | -40℃~+350℃ |
Operating condition | Temperature: -25℃~60℃ |
Humidity: 5%~90% | |
Nominal pressure | ≤1.6Mpa (offer ≤2.5Mpa and ≤4.0Mpa customization) |
Power | DC24V <0.5W |
Frequency range of input signal | 0~3000Hz |
Output | Current output:4~20mA |
insulation resistance | >500MΩ |
WSLU Digital Display Type
Intelligent integrated display vortex flowmeter is a new intelligent instrument with multi-function and integration, which is developed with advanced low-power MSP430 chip as the core. The converter has multi-point coefficient correction function. This series of products adopt segment code LCD display with high contrast and low power. Two display units are optional. A variety of electrical signal output modes are optional, especially suitable for quantitative control. This series of products can not only display the commonly used volume flow units, but also display the mass flow units by setting the measured medium density. On the basis of the above functions, in order to meet the different needs of users, users can choose the communication function of MODBUS protocol based on RS485 interface.
Medium | Air, oxygen, nitrogen, coal gas, natural gas, chemical gas,Saturated steam, superheated steam,Water, high temperature water, oil, beverage, chemical liquids etc.. |
Caliber | Flange connection:DN15~DN300 |
Accuracy | Pipe type: Class 1.0 Insertion type: Class 2.5 |
Range ratio | 1:10~1:20 |
Flow range | 0.5~10m/s |
Medium temperature | -40℃~+350℃ |
Operating condition | Temperature: -25℃~60℃ |
Humidity: 5%~90% | |
Nominal pressure | ≤1.6Mpa (offer ≤2.5Mpa and ≤4.0Mpa customization) |
Power | DC24V <0.5W |
Battery powered | DC3V/3.6V Minimum operating voltage:>2V/2.1V Working current:1170±20μA/300±5μA |
Frequency range of input signal | 0~3000Hz |
Output | Current output:4~20mA,0~20mA |
insulation resistance | >500MΩ |
communication interface | RS485 |
Communication protocol | MODBUS-RTU |
WSLU Temperature and Pressure Compensation Type
Medium | Air, oxygen, nitrogen, coal gas, natural gas, chemical gas,Saturated steam, superheated steam,Water, high temperature water, oil, beverage, chemical liquids etc.. |
Caliber | Flange connection:DN15~DN300 |
Accuracy | Pipe type: Class 1.0 Insertion type: Class 2.5 |
Range ratio | 1:10~1:20 |
Flow range | 0.5~10m/s |
Medium temperature | -40℃~+350℃ |
Operating condition | Temperature: -25℃~60℃ |
Humidity: 5%~90% | |
Nominal pressure | ≤1.6Mpa (offer ≤2.5Mpa and ≤4.0Mpa customization) |
Power | DC24V, <1.0W |
Battery powered | DC3.6V |
Frequency range of input signal | 0~3000Hz |
Output | Current output:4~20mA |
Alarm Pulse Output | Pulse output:High level>22V,Low level<0.8V |
insulation resistance | >500MΩ |
communication interface | Two-wire current HART communication |
Product selection
WSLU- |
|
|
|
|
|
|
|
|
|
| Note |
Nominal diameter | DNXX |
|
|
|
|
|
|
|
|
| DN15~DN1800 (mm) |
Structure | F |
|
|
|
|
|
|
|
| Remote type with display | |
Y |
|
|
|
|
|
|
|
| Compact type with display | ||
Medium | A |
|
|
|
|
|
|
| Liquid | ||
B |
|
|
|
|
|
|
| General gas | |||
C |
|
|
|
|
|
|
| Saturated gas | |||
D |
|
|
|
|
|
|
| Superheated steam | |||
Nominal pressure | 16 |
|
|
|
|
|
| 1.6Mpa | |||
XX |
|
|
|
|
|
| Customization | ||||
Max. temp. of medium | M |
|
|
|
|
| <250℃ | ||||
H |
|
|
|
|
| >250℃ | |||||
Other function | P |
|
|
|
| With pressure compensation | |||||
T |
|
|
|
| With temperature compensation | ||||||
PT |
|
|
|
| With pressure and temperature compensation | ||||||
Power | 1 |
|
|
| 12~28VDC | ||||||
2 |
|
|
| 3.6V lithium battery (on site display) | |||||||
3 |
|
|
| 85~265VAC (Remote display) | |||||||
Output | A |
|
| 4-20mA | |||||||
M |
|
| Voltage pulse | ||||||||
H |
|
| HART | ||||||||
R1 |
|
| RS232 | ||||||||
R2 |
|
| RS485 | ||||||||
Installation | 1 |
| Flange | ||||||||
2 |
| Clamp flange | |||||||||
3 |
| Insertion | |||||||||
4 |
| Thread | |||||||||
5 |
| Clamp | |||||||||
Explosion proof | A | No explosion proof | |||||||||
B | Intrinsic explosion proof | ||||||||||
G | Flame proof | ||||||||||