Product Overview
XBD series fire pump is our company according to the requirements of the actual market needs for fire pump and special use, strictly in accordance with the new fire products fire pump performance requirements and test methods of standard research and development the new GB6245-1998 ". Through the national fire equipment quality supervision and testing center testing, the performance indicators have reached or exceeded the standard requirements, and obtained the national fire products certification.
Product features
Compact structure, small volume, beautiful appearance, its vertical structure decided to install a small area, center of gravity into the center of the pump foot, thus enhancing the stability of the operation and the service life of the pump.
Inlet and outlet are horizontal, simplified, the connection of pipeline.
Inlet and outlet can be installed into the same direction or 90 degrees, 180 degrees, 270 degrees with several small direction to meet the connection in different occasions.
Head can be increased or decreased pump series and the combination of cutting impeller diameter to be met, without changing the installation area, which is not possessed by other pump.
Motor plus rain cover, the pump can be placed outdoors, cancel the pump to save construction costs.
Pump rotor with small deflection, and the selection of 4 pole motor, therefore, stable running, small vibration, low noise, long service life.
use products
Fire hydrant XBD series fire pump is mainly used for various enterprises and institutions, engineering construction, high-level people ha and other fixed fire extinguishing system, system of towel of the automatic sprinkler system, called for the transport of 100 DEG C containing no solid particles of water and physical and chemical properties similar to water medium, and can be used for fire protection, life and production shared water supply system and construction, municipal water supply and drainage etc..
Model description:
Performance parameters
XBD**/5-50DL Table parameters of the vertical multistage fire pump
| Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD1.6/5-50DL | 2 | 3.5 5.0 6.0 | 12.6 18.0 21.6 | 0.16 | 3 | 54 |
| XBD1.8/5-50DL | 0.18 |
| XBD2.0/5-50DL | 0.20 |
| XBD2.2/5-50DL | 0.22 |
| XBD2.6/5-50DL | 3 | 3.5 5.0 6.0 | 12.6 18.0 21.6 | 0.26 | 3 | 54 |
| XBD2.8/5-50DL | 0.28 |
| XBD3.0/5-50DL | 0.30 |
| XBD3.2/5-50DL | 0.32 |
| XBD3.6/5-50DL | 4 | 3.5 5.0 6.0 | 12.6 18.0 21.6 | 0.36 | 4 | 54 |
| XBD3.8/5-50DL | 0.38 |
| XBD4.0/5-50DL | 0.40 |
| XBD4.2/5-50DL | 0.42 |
| XBD4.6/5-50DL | 5 | 3.5 5.0 6.0 | 12.6 18.0 21.6 | 0.46 | 5.5 | 54 |
| XBD4.8/5-50DL | 0.48 |
| XBD5.0/5-50DL | 0.50 |
| XBD5.2/5-50DL | 0.52 |
| XBD5.6/5-50DL | 6 | 3.5 5.0 6.0 | 12.6 18.0 21.6 | 0.56 | 5.5 | 54 |
| XBD5.8/5-50DL | 0.58 |
| XBD6.0/5-50DL | 0.60 |
| XBD6.2/5-50DL | 0.62 |
| XBD6.6/5-50DL | 7 | 3.5 5.0 6.0 | 12.6 18.0 21.6 | 0.66 | 7.5 | 54 |
| XBD6.8/5-50DL | 0.68 |
| XBD7.0/5-50DL | 0.70 |
| XBD7.2/5-50DL | 0.72 |
| XBD7.6/5-50DL | 8 | 3.5 5.0 6.0 | 12.6 18.0 21.6 | 0.76 | 7.5 | 54 |
| XBD7.8/5-50DL | 0.78 |
| XBD8.0/5-50DL | 0.80 |
| XBD8.2/5-50DL | 0.82 |
| XBD8.6/5-50DL | 9 | 3.5 5.0 6.0 | 12.6 18.0 21.6 | 0.86 | 7.5 | 54 |
| XBD8.8/5-50DL | 0.88 |
| XBD9.0/5-50DL | 0.90 |
| XBD9.2/5-50DL | 0.92 |
XBD**/10-65DL Table parameters of the vertical multistage fire pump
| Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD2.2/10-65DL | 2 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 0.22 | 5.5 | 62 | | XBD2.5/10-65DL | 0.25 | | XBD2.8/10-65DL | 0.28 | | XBD3.0/10-65DL | 0.30 | | XBD3.6/10-65DL | 3 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 0.36 | 7.5 | 62 | | XBD4.0/10-65DL | 0.40 | | XBD4.2/10-65DL | 0.42 | | XBD4.5/10-65DL | 0.45 | | XBD5.0/10-65DL | 4 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 0.50 | 11 | 62 | | XBD5.2/10-65DL | 0.52 | | XBD5.6/10-65DL | 0.56 | | XBD6.0/10-65DL | 0.60 | | XBD6.4/10-65DL | 5 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 0.64 | 15 | 62 | | XBD6.8/10-65DL | 0.68 | | XBD7.0/10-65DL | 0.70 | | XBD7.2/10-65DL | 0.72 | | XBD7.8/10-65DL | 6 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 0.78 | 15 | 62 | | XBD8.0/10-65DL | 0.80 | | XBD8.4/10-65DL | 0.84 | | XBD8.6/10-65DL | 0.86 | | XBD9.2/10-65DL | 7 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 0.92 | 18.5 | 62 | | XBD9.5/10-65DL | 0.95 | | XBD9.8/10-65DL | 0.98 | | XBD10.0/10-65DL | 1.00 | | XBD10.8/10-65DL | 8 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 1.08 | 22 | 62 | | XBD11.0/10-65DL | 1.10 | | XBD11.2/10-65DL | 1.12 | | XBD11.5/10-65DL | 1.15 | | XBD12.0/10-65DL | 9 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 1.20 | 22 | 62 | | XBD12.2/10-65DL | 1.22 | | XBD12.6/10-65DL | 1.26 | | XBD12.8/10-65DL | 1.28 | | XBD13.4/10-65DL | 10 | 7.0 10.0 12.0 | 25.2 36.0 43.2 | 1.34 | 30 | 62 | | XBD13.6/10-65DL | 1.36 | | XBD14.0/10-65DL | 1.40 | | XBD14.2/10-65DL | 1.42 |
|
XBD**/15-80DL Table parameters of the vertical multistage fire pump
| Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD3.6/15-80DL | 2 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 0.36 | 11 | 70 |
| XBD3.8/15-80DL | 0.38 |
| XBD4.0/15-80DL | 0.40 |
| XBD4.2/15-80DL | 0.42 |
| XBD5.6/15-80DL | 3 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 0.56 | 15 | 70 |
| XBD5.8/15-80DL | 0.58 |
| XBD6.0/15-80DL | 0.60 |
| XBD6.215-80DL | 0.62 |
| XBD7.6/15-80DL | 4 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 0.76 | 22 | 70 |
| XBD7.8/15-80DL | 0.78 |
| XBD8.0/15-80DL | 0.80 |
| XBD8.2/15-80DL | 0.82 |
| XBD9.6/15-80DL | 5 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 0.96 | 30 | 70 |
| XBD9.8/15-80DL | 0.98 |
| XBD10.0/15-80DL | 1.00 |
| XBD10.2/15-80DL | 1.02 |
| XBD11.6/15-80DL | 6 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 1.16 | 30 | 70 |
| XBD11.8/15-80DL | 1.18 |
| XBD12.0/15-80DL | 1.20 |
| XBD12.2/15-80DL | 1.22 |
| XBD13.6/15-80DL | 7 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 1.36 | 37 | 70 |
| XBD13.8/15-80DL | 1.38 |
| XBD14.0/15-80DL | 1.40 |
| XBD14.2/15-80DL | 1.42 |
| XBD15.6/15-80DL | 8 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 1.56 | 45 | 70 |
| XBD15.8/15-80DL | 1.58 |
| XBD16.0/15-80DL | 1.60 |
| XBD16.2/15-80DL | 1.62 |
| XBD17.6/15-80DL | 9 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 1.76 | 45 | 70 |
| XBD17.8/15-80DL | 1.78 |
| XBD18.0/15-80DL | 1.80 |
| XBD18.2/15-80DL | 1.82 |
| XBD19.6/15-80DL | 10 | 10.5 15.0 18.0 | 37.8 54.0 64.8 | 1.96 | 55 | 70 |
| XBD19.8/15-80DL | 1.98 |
| XBD20.0/15-80DL | 2.00 |
| XBD20.2/15-80DL | 2.02 |
XBD**/20-100DL Table parameters of the vertical multistage fire pump
| Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD3.6/20-100DL | 2 | 14 20 24 | 50.4 72.0 86.4 | 0.36 | 15 | 72 |
| XBD3.8/20-100DL | 0.38 |
| XBD4.0/20-100DL | 0.40 |
| XBD4.2/20-100DL | 0.42 |
| XBD5.5/20-100DL | 3 | 14 20 24 | 50.4 72.0 86.4 | 0.55 | 18.5 | 72 |
| XBD5.8/20-100DL | 0.58 |
| XBD6.0/20-100DL | 0.60 |
| XBD6.2/20-100DL | 0.62 |
| XBD7.6/20-100DL | 4 | 14 20 24 | 50.4 72.0 86.4 | 0.76 | 30 | 72 |
| XBD7.8/20-100DL | 0.78 |
| XBD8.0/20-100DL | 0.80 |
| XBD8.2/20-100DL | 0.82 |
| XBD9.3/20-100DL | 5 | 14 20 24 | 50.4 72.0 86.4 | 0.93 | 37 | 72 |
| XBD9.8/20-100DL | 0.98 |
| XBD10.0/20-100DL | 1.00 |
| XBD10.2/20-100DL | 1.02 |
| XBD1160/20-100DL | 6 | 14 20 24 | 50.4 72.0 86.4 | 1.16 | 37 | 72 |
| XBD11.8/20-100DL | 1.18 |
| XBD12.0/20-100DL | 1.20 |
| XBD12.2/20-100DL | 1.22 |
| XBD13.6/20-100DL | 7 | 14 20 24 | 50.4 72.0 86.4 | 1.36 | 45 | 72 |
| XBD13.8/20-100DL | 1.38 |
| XBD14.0/20-100DL | 1.40 |
| XBD14.2/20-100DL | 1.42 |
| XBD15.6/20-100DL | 8 | 14 20 24 | 50.4 72.0 86.4 | 1.56 | 55 | 72 |
| XBD15.8/20-100DL | 1.58 |
| XBD16.0/20-100DL | 1.60 |
| XBD16.2/20-100DL | 1.62 |
| XBD17.6/20-100DL | 9 | 14 20 24 | 50.4 72.0 86.4 | 1.76 | 55 | 72 |
| XBD17.8/20-100DL | 1.78 |
| XBD18.0/20-100DL | 1.80 |
| XBD18.2/20-100DL | 1.82 |
| XBD19.6/20-100DL | 10 | 14 20 24 | 50.4 72.0 86.4 | 1.96 | 75 | 72 |
| XBD19.8/20-100DL | 1.98 |
| XBD20.0/20-100DL | 2.00 |
| XBD20.2/20-100DL | 2.02 |
XBD**/25-100DL Fire pump parameter table | Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD3.6/25-100DL | 2 | 17.5 25.0 30.0 | 63 90.0 180 | 0.36 | 18.5 | 72 | | XBD3.8/25-100DL | 0.38 | | XBD4.0/25-100DL | 0.40 | | XBD4.2/25-100DL | 0.42 | | XBD5.6/25-100DL | 3 | 17.5 25.0 30.0 | 63 90.0 180 | 0.56 | 30 | 72 | | XBD5.8/25-100DL | 0.58 | | XBD6.0/25-100DL | 0.60 | | XBD6.2/25-100DL | 0.62 | | XBD7.6/25-100DL | 4 | 17.5 25.0 30.0 | 63 90.0 180 | 0.76 | 37 | 72 | | XBD7.8/25-100DL | 0.78 | | XBD8.0/25-100DL | 0.80 | | XBD8.2/25-100DL | 0.82 | | XBD9.6/25-100DL | 5 | 17.5 25.0 30.0 | 63 90.0 180 | 0.96 | 45 | 72 | | XBD9.8/25-100DL | 0.98 | | XBD10.0/25-100DL | 1.00 | | XBD10.2/25-100DL | 1.02 | | XBD11.6/25-100DL | 6 | 17.5 25.0 30.0 | 63 90.0 180 | 1.16 | 55 | 72 | | XBD11.8/25-100DL | 1.18 | | XBD12.0/25-100DL | 1.20 | | XBD12.2/25-100DL | 1.22 | | XBD13.6/25-100DL | 7 | 17.5 25.0 30.0 | 63 90.0 180 | 1.36 | 75 | 72 | | XBD13.8/25-100DL | 1.38 | | XBD14.0/25-100DL | 1.40 | | XBD14.2/25-100DL | 1.42 | | XBD15.6/25-100DL | 8 | 17.5 25.0 30.0 | 63 90.0 180 | 1.56 | 75 | 72 | | XBD15.8/25-100DL | 1.58 | | XBD16.0/25-100DL | 1.60 | | XBD16.2/25-100DL | 1.62 | | XBD17.6/25-100DL | 9 | 17.5 25.0 30.0 | 63 90.0 180 | 1.76 | 90 | 72 | | XBD17.8/25-100DL | 1.78 | | XBD18.0/25-100DL | 1.80 | | XBD18.2/25-100DL | 1.82 | | XBD19.6/25-100DL | 10 | 17.5 25.0 30.0 | 63 90.0 180 | 1.96 | 90 | 72 | | XBD19.8/25-100DL | 1.98 | | XBD20.0/25-100DL | 2.00 | | XBD20.2/25-100DL | 2.02 |
|
XBD**/30-100(125)DL Fire pump parameter table
| Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD3.6/30-100(125)DL | 2 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 0.36 | 18.5 | 72 | | XBD3.8/30-100(125)DL | 0.38 | | XBD4.0/30-100(125)DL | 0.40 | | XBD4.2/30-100(125)DL | 0.42 | | XBD5.6/30-100(125)DL | 3 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 0.56 | 30 | 72 | | XBD5.8/30-100(125)DL | 0.58 | | XBD6.0/30-100(125)DL | 0.60 | | XBD6.2/30-100(125)DL | 0.62 | | XBD7.6/30-100(125)DL | 4 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 0.76 | 37 | 72 | | XBD7.8/30-100(125)DL | 0.78 | | XBD8.0/30-100(125)DL | 0.80 | | XBD8.2/30-100(125)DL | 0.82 | | XBD9.6/30-100(125)DL | 5 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 0.96 | 45 | 72 | | XBD9.8/30-100(125)DL | 0.98 | | XBD10.0/30-100(125)DL | 1.00 | | XBD10.2/30-100(125)DL | 1.02 | | XBD11.6/30-100(125)DL | 6 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 1.16 | 55 | 72 | | XBD11.8/30-100(125)DL | 1.18 | | XBD12.0/30-100(125)DL | 1.20 | | XBD12.2/30-100(125)DL | 1.22 | | XBD13.6/30-100(125)DL | 7 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 1.36 | 75 | 72 | | XBD13.8/30-100(125)DL | 1.38 | | XBD14.0/30-100(125)DL | 1.40 | | XBD14.2/30-100(125)DL | 1.42 | | XBD15.6/30-100(125)DL | 8 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 1.56 | 75 | 72 | | XBD15.8/30-100(125)DL | 1.58 | | XBD16.0/30-100(125)DL | 1.60 | | XBD16.2/30-100(125)DL | 1.62 | | XBD17.6/30-100(125)DL | 9 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 1.76 | 90 | 72 | | XBD17.8/30-100(125)DL | 1.78 | | XBD18.0/30-100(125)DL | 1.80 | | XBD18.2/30-100(125)DL | 1.82 | | XBD19.6/30-100(125)DL | 10 | 21.0 30.0 36.0 | 75.6 108.0 129.6 | 1.96 | 90 | 72 | | XBD19.8/30-100(125)DL | 1.98 | | XBD20.0/30-100(125)DL | 2.00 | | XBD20.2/30-100(125)DL | 2.02 |
|
■ XBD**/35-125(150)DL Fire pump parameter table | Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD3.6/35-125(150)DL | 2 | 24.5 35.0 42.0 | 88.2 126 151 | 0.36 | 30 | 80 | | XBD3.8/35-125(150)DL | 0.38 | | XBD4.0/35-125(150)DL | 0.40 | | XBD4.2/35-125(150)DL | 0.42 | | XBD5.6/35-125(150)DL | 3 | 24.5 35.0 42.0 | 88.2 126 151 | 0.56 | 37 | 80 | | XBD5.8/35-125(150)DL | 0.58 | | XBD6.0/35-125(150)DL | 0.60 | | XBD6.2/35-125(150)DL | 0.62 | | XBD7.6/35-125(150)DL | 4 | 24.5 35.0 42.0 | 88.2 126 151 | 0.76 | 45 | 80 | | XBD7.8/35-125(150)DL | 0.78 | | XBD8.0/35-125(150)DL | 0.80 | | XBD8.2/35-125(150)DL | 0.82 | | XBD9.6/35-125(150)DL | 5 | 24.5 35.0 42.0 | 88.2 126 151 | 0.96 | 55 | 80 | | XBD9.8/35-125(150)DL | 0.98 | | XBD10.0/35-125(150)DL | 1.00 | | XBD10.2/35-125(150)DL | 1.02 | | XBD11.6/35-125(150)DL | 6 | 24.5 35.0 42.0 | 88.2 126 151 | 1.16 | 75 | 80 | | XBD11.8/35-125(150)DL | 1.18 | | XBD12.0/35-125(150)DL | 1.20 | | XBD12.2/35-125(150)DL | 1.22 | | XBD13.6/35-125(150)DL | 7 | 24.5 35.0 42.0 | 88.2 126 151 | 1.36 | 75 | 80 | | XBD13.8/35-125(150)DL | 1.38 | | XBD14.0/35-125(150)DL | 1.40 | | XBD14.2/35-125(150)DL | 1.42 | | XBD15.6/35-125(150)DL | 8 | 24.5 35.0 42.0 | 88.2 126 151 | 1.56 | 90 | 80 | | XBD15.8/35-125(150)DL | 1.58 | | XBD16.0/35-125(150)DL | 1.60 | | XBD16.2/35-125(150)DL | 1.62 | | XBD17.6/35-125(150)DL | 9 | 24.5 35.0 42.0 | 88.2 126 151 | 1.76 | 110 | 80 | | XBD17.8/35-125(150)DL | 1.78 | | XBD18.0/35-125(150)DL | 1.80 | | XBD18.2/35-125(150)DL | 1.82 | | XBD19.6/35-125(150)DL | 10 | 24.5 35.0 42.0 | 88.2 126 151 | 1.96 | 132 | 80 | | XBD19.8/35-125(150)DL | 1.98 | | XBD20.0/35-125(150)DL | 2.00 | | XBD20.2/35-125(150)DL | 2.02 |
|
■ XBD**/40-150DL Fire pump parameter table | Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD3.6/40-150DL | 2 | 28 40 48 | 100 144 172 | 0.36 | 30 | 80 | | XBD3.8/40-150DL | 0.38 | | XBD4.0/40-150DL | 0.40 | | XBD4.2/40-150DL | 0.42 | | XBD5.6/40-150DL | 3 | 28 40 48 | 100 144 172 | 0.56 | 37 | 80 | | XBD5.8/40-150DL | 0.58 | | XBD6.0/40-150DL | 0.60 | | XBD6.2/40-150DL | 0.62 | | XBD7.6/40-150DL | 4 | 28 40 48 | 100 144 172 | 0.76 | 45 | 80 | | XBD7.8/40-150DL | 0.78 | | XBD8.0/40-150DL | 0.80 | | XBD8.2/40-150DL | 0.82 | | XBD9.6/40-150DL | 5 | 28 40 48 | 100 144 172 | 0.96 | 55 | 80 | | XBD9.8/40-150DL | 0.98 | | XBD10.0/40-150DL | 1.00 | | XBD10.2/40-150DL | 1.02 | | XBD11.6/40-150DL | 6 | 28 40 48 | 100 144 172 | 1.16 | 75 | 80 | | XBD11.8/40-150DL | 1.18 | | XBD12.0/40-150DL | 1.20 | | XBD12.2/40-150DL | 1.22 | | XBD13.6/40-150DL | 7 | 28 40 48 | 100 144 172 | 1.36 | 75 | 80 | | XBD13.8/40-150DL | 1.38 | | XBD14.0/40-150DL | 1.40 | | XBD14.2/40-150DL | 1.42 | | XBD15.6/40-150DL | 8 | 28 40 48 | 100 144 172 | 1.56 | 90 | 80 | | XBD15.8/40-150DL | 1.58 | | XBD16.0/40-150DL | 1.60 | | XBD16.2/40-150DL | 1.62 | | XBD17.6/40-150DL | 9 | 28 40 48 | 100 144 172 | 1.76 | 110 | 80 | | XBD17.8/40-150DL | 1.78 | | XBD18.0/40-150DL | 1.80 | | XBD18.2/40-150DL | 1.82 | | XBD19.6/40-150DL | 10 | 28 40 48 | 100 144 172 | 1.96 | 132 | 80 | | XBD19.8/40-150DL | 1.98 | | XBD20.0/40-150DL | 2.00 | | XBD20.2/40-150DL | 2.02 |
|
■ XBD**/45-150DL Fire pump parameter table | Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD4.6/45-150DL | 2 | 31.5 45.0 54.0 | 113 162 194 | 0.46 | 37 | 80 | | XBD4.8/45-150DL | 0.48 | | XBD5.0/45-150DL | 0.50 | | XBD5.2/45-150DL | 0.52 | | XBD7.0/45-150DL | 3 | 31.5 45.0 54.0 | 113 162 194 | 0.70 | 55 | 80 | | XBD7.2/45-150DL | 0.72 | | XBD7.5/45-150DL | 0.75 | | XBD7.8/45-150DL | 0.78 | | XBD9.6/45-150DL | 4 | 31.5 45.0 54.0 | 113 162 194 | 0.96 | 75 | 80 | | XBD9.8/45-150DL | 0.98 | | XBD10.0/45-150DL | 1.00 | | XBD10.2/45-150DL | 1.02 | | XBD12.0/45-150DL | 5 | 31.5 45.0 54.0 | 113 162 194 | 1.20 | 90 | 80 | | XBD12.2/45-150DL | 1.22 | | XBD12.5/45-150DL | 1.25 | | XBD12.8/45-150DL | 1.28 | | XBD14.6/45-150DL | 6 | 31.5 45.0 54.0 | 113 162 194 | 1.46 | 110 | 80 | | XBD14.8/45-150DL | 1.48 | | XBD15.0/45-150DL | 1.50 | | XBD15.2/45-150DL | 1.52 | | XBD17.0/45-150DL | 7 | 31.5 45.0 54.0 | 113 162 194 | 1.70 | 132 | 80 | | XBD17.2/45-150DL | 1.72 | | XBD17.5/45-150DL | 1.75 | | XBD17.8/45-150DL | 1.78 | | XBD19.6/45-150DL | 8 | 31.5 45.0 54.0 | 113 162 194 | 1.96 | 132 | 80 | | XBD19.8/45-150DL | 1.98 | | XBD20.0/45-150DL | 2.00 | | XBD20.2/45-150DL | 2.02 | | XBD22.0/45-150DL | 9 | 31.5 45.0 54.0 | 113 162 194 | 2.20 | 160 | 80 | | XBD22.2/45-150DL | 2.22 | | XBD22.5/45-150DL | 2.25 | | XBD22.8/45-150DL | 2.28 | | XBD24.6/45-150DL | 10 | 31.5 45.0 54.0 | 113 162 194 | 2.46 | 160 | 80 | | XBD24.8/45-150DL | 2.48 | | XBD25.0/45-150DL | 2.50 | | XBD25.2/45-150DL | 2.52 |
|
| Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency (%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD4.6/50-150DL | 2 | 35 50 60 | 126 180 216 | 0.46 | 37 | 80 | | XBD4.8/50-150DL | 0.48 | | XBD5.0/50-150DL | 0.50 | | XBD5.2/50-150DL | 0.52 | | XBD7.0/50-150DL | 3 | 35 50 60 | 126 180 216 | 0.70 | 55 | 80 | | XBD7.2/50-150DL | 0.72 | | XBD7.5/50-150DL | 0.75 | | XBD7.8/50-150DL | 0.78 | | XBD9.6/50-150DL | 4 | 35 50 60 | 126 180 216 | 0.96 | 75 | 80 | | XBD9.8/50-150DL | 0.98 | | XBD10.0/50-150DL | 1.00 | | XBD10.2/50-150DL | 1.02 | | XBD12.0/50-150DL | 5 | 35 50 60 | 126 180 216 | 1.20 | 90 | 80 | | XBD12.2/50-150DL | 1.22 | | XBD12.5/50-150DL | 1.25 | | XBD12.8/50-150DL | 1.28 | | XBD14.6/50-150DL | 6 | 35 50 60 | 126 180 216 | 1.46 | 110 | 80 | | XBD14.8/50-150DL | 1.48 | | XBD15.0/50-150DL | 1.50 | | XBD15.2/50-150DL | 1.52 | | XBD17.0/50-150DL | 7 | 35 50 60 | 126 180 216 | 1.70 | 132 | 80 | | XBD17.2/50-150DL | 1.72 | | XBD17.5/50-150DL | 1.75 | | XBD17.8/50-150DL | 1.78 | | XBD19.6/50-150DL | 8 | 35 50 60 | 126 180 216 | 1.96 | 132 | 80 | | XBD19.8/50-150DL | 1.98 | | XBD20.0/50-150DL | 2.00 | | XBD20.2/50-150DL | 2.02 | | XBD22.0/50-150DL | 9 | 35 50 60 | 126 180 216 | 2.20 | 160 | 80 | | XBD22.2/50-150DL | 2.22 | | XBD22.5/50-150DL | 2.25 | | XBD22.8/50-150DL | 2.28 | | XBD24.6/50-150DL | 10 | 35 50 60 | 126 180 216 | 2.46 | 160 | 80 | | XBD24.8/50-150DL | 2.48 | | XBD25.0/50-150DL | 2.50 | | XBD25.2/50-150DL | 2.52 | | XBD17.4/75-200DL | 6 | 52 75 90 | 187 270 324 | 17.4 | 200 | 79 | | XBD17.7/75-200DL | 17.7 |
|
■ XBD**/75(80)-200DL Fire pump parameter table | Model | Series | Flow | Outlet pressure (Mpa) | Motor power (kw) | Efficiency(%) |
|---|
| (L/s) | (m3/h) |
|---|
| XBD3.6/80-200DL | 2 | 56 80 96 | 200 288 345 | 0.36 | 55 | 79 | | XBD3.8/80-200DL | 0.38 | | XBD4.0/80-200DL | 0.40 | | XBD4.2/80-200DL | 0.42 | | XBD5.6/80-200DL | 3 | 56 80 96 | 200 288 345 | 0.56 | 75 | 79 | | XBD5.8/80-200DL | 0.58 | | XBD6.0/80-200DL | 0.60 | | XBD6.2/80-200DL | 0.62 | | XBD7.6/80-200DL | 4 | 56 80 96 | 200 288 345 | 0.76 | 110 | 79 | | XBD7.8/80-200DL | 0.78 | | XBD8.0/80-200DL | 0.80 | | XBD8.2/80-200DL | 0.82 | | XBD9.6/80-200DL | 5 | 56 80 96 | 200 288 345 | 0.96 | 132 | 79 | | XBD9.8/80-200DL | 0.98 | | XBD10.0/80-200DL | 1.00 | | XBD10.2/80-200DL | 1.02 | | XBD11.6/80-200DL | 6 | 56 80 96 | 200 288 345 | 1.16 | 160 | 79 | | XBD11.8/80-200DL | 1.18 | | XBD12.0/80-200DL | 1.20 | | XBD12.2/80-200DL | 1.22 | | XBD5.4/75-200DL | 2 | 52 75 90 | 187 270 324 | 0.54 | 75 | 79 | | XBD5.7/75-200DL | 0.57 | | XBD6.0/75-200DL | 0.60 | | XBD6.3/75-200DL | 0.63 | | XBD8.4/75-200DL | 3 | 52 75 90 | 187 270 324 | 0.84 | 110 | 79 | | XBD8.7/75-200DL | 0.87 | | XBD9.0/75-200DL | 0.90 | | XBD9.3/75-200DL | 0.93 | | XBD11.4/75-200DL | 4 | 52 75 90 | 187 270 324 | 1.14 | 132 | 79 | | XBD11.73/75-200DL | 1.17 | | XBD12.0/75-200DL | 1.20 | | XBD12.3/75-200DL | 1.23 | | XBD14.4/75-200DL | 5 | 52 75 90 | 187 270 324 | 1.44 | 160 | 79 | | XBD14.7/75-200DL | 1.47 | | XBD15.0/75-200DL | 1.50 | | XBD15.3/75-200DL | 1.53 | | XBD18.0/75-200DL | 6 | 52 75 90 | 187 270 324 | 18.0 | 200 | 779 | | XBD18.3/75-200DL | 18.3 |
|