Membership
Help
Shandong BOS Energy Technology Co., Ltd
Shandong BOS Energy Technology Co., Ltd
1. High reliability
The main components are imported components, originalMitsubishi IGBT inverter module, drive protection for the original Mitsubishimovement, a perfect drive protection circuit to ensure reliable IGBT work.
2. Dynamic response speed (patented technology)
The use of double closed-loop feedback circuit, the innercurrent loop to ensure that the nonlinear load waveform distortion; outer ringvoltage ring to ensure sudden increase in load pressure drop <1%, thereaction rate is less than 2mS, the control circuit for analog circuits,anti-interference ability, , Some manufacturers use the digital controlsampling required by the A / D conversion, calculation, D / A conversion,control process is long, slow response, poor anti-jamming capability and easyto crash.
3. Three-phase power supply can adapt to any unbalancedload
Three-phase power supply can be three-phase system, butalso single-phase sub-tune. Three-phase power supply main circuit and controlcircuit in accordance with the three sets of independent single-phase powersupply design. The main circuit is composed of a rectifier, a DC filter, aninverter, an AC filter and a transformer. Three sets of single-phase invertercircuit output mutual difference 120 angle, independent of each other in thetransformer primary side, connected to the transformer secondary star, theoutput of the required three-phase AC. Voltage and waveform control Forsingle-phase output, three independent single-phase controllers are used sothat any phase of a three-phase power supply can be used as a single-phasepower supply independently and can accommodate any unbalanced load, resultingin a significant increase The power of the load adaptability. Really do a loadimbalance.
4. Man-machine interface is good, table source one, highaccuracy
Voltage, frequency, current, power / power factor fourwindow measurement display, accuracy of 0.5, the source table integration.
5. Great load capacity
Power components of reasonable application, can withstand3 times the rated current, and will not cause pressure drop.
6. Excellent stability
Frequency stability ≤ 0.01%, load stability ≤ 1%, theoutput frequency of oscillation generated by the quartz oscillator, it is verystable and accurate.
Model | 11005 | 11010 | 11030 | 11050 | 11100 | 31150 | 31200 | 313000 | 31450 | 311000 | ||||
Capacity(VA) | 500 | 1K | 3K | 5K | 10K | 15K | 20K | 30K | 45K | 100K | ||||
Output limit currency | LOW(A) | 4.2 | 8.4 | 24 | 42 | 84 | 126 | 168 | 250 | 375 | 840 | |||
HIGH(A) | 2.1 | 4.2 | 12 | 21 | 42 | 63 | 84 | 125 | 188 | 420 | ||||
Circuit model | IGBT/SPWM pulse width adjustment mode | |||||||||||||
Output frequency | 50Hz/60Hz 45-65Hz | |||||||||||||
Load stability | ≤±1% | |||||||||||||
frequency stability | fixed-frequency≤±0.01%,frequency modulation≤±0.1% | |||||||||||||
Input voltage | 220V±10% | 380V±10% | ||||||||||||
Phase | single phase | three phase four wire | ||||||||||||
Wave distortion | ≤3% | |||||||||||||
Output voltage | low-grade:0-150V continuous-tuning; high-grade:0 - 300 V continuous-tuning | |||||||||||||
Reaction time | ≤2mS | |||||||||||||
frequency meter | 0.1Hz | |||||||||||||
Voltage meter | 0.1V | |||||||||||||
Current meter | 0. 1A | |||||||||||||
Power meter | 0.1W | |||||||||||||
Ammeter display | Frequency, voltage, current, power or PF 4 number display | |||||||||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | |||||||||||||
Insulation reactance | 500Vdc 20MΩ | |||||||||||||
Pressure endurance insulation | 1500Vac/5mA/1min | |||||||||||||
Cooling model | Compulsive fan cooling | |||||||||||||
Working temperature | -10℃-45℃ | |||||||||||||
Relative humidity | 0-90%(No condensing) | |||||||||||||
Altitude | 1500meters | |||||||||||||
Dimension (W×L×H)mm | 410*440*135 | 460*440*220 | 560*350*600 | 660*400*700 | 830*450*1100 | 1160*520*1370 | ||||||||
Model 13060 13100 33150 33300 331000 332000 333000 334500 336000 338000 Capacity(KVA) 6 10 15 30 100 200 300 450 600 800 Output limit currency LOW(A) 16.8 27.6 41.6 84 276 none HIGH(A) 8.4 13.8 20.8 42 138 260 400 600 800 1050 Pulse
&l