Features of metal cylindrical proximity sensor:
● Reverse polarity protection;
● Short-circuit protection (IM8、IM12、IM18、IM30 DC type);
● Long-life & high reliability;
● Yellow Led indicates working status of sensor;
● Economical and easy to operate;
● Alternatives for mini switch and limit switch;
● Delay at power-up,guard against false pulse;
Proximity sensor | |||||||
Model | IM18B-05-DO | IM18N-08-DO | IM18B-05-NO | IM18N-05-PO | IM18B-08-NO | IM18N-08-PO | |
General parameters: | |||||||
Installation method | Flush style | Non-flush | Flush style | Non-flush | Flush style | Non-flush | |
Detection distance | 5mm±10% | 8mm±10% | 5mm±10% | 5mm±10% | 8mm±10% | 8mm±10% | |
Return difference | ≤15% | ||||||
Set distance | 0~4mm | 0~6.4mm | 0~4 mm | 0~6.4 mm | 0~1.6 mm | 0~3.2 mm | |
Mechanical/Electronic Parameters: | |||||||
Operating voltage | 10-30VDC | ||||||
No-load current | Max.5mA | Max.8mA | |||||
Voltage drop | Max.2.5V | Max.1.7V | |||||
Operating frequency | 350Hz | 200Hz | 500Hz | 300 Hz | 500Hz | 300 Hz | |
Indicator light | Operation indicator yellow | ||||||
Function | Short circuit protection,over voltage protection,reverse polarity protection | ||||||
Action mode | Normally closed (DC) / normally open (DO) depending on the specific model | Normally closed (NC)/Normally open (NO) depending on the specific model | |||||
Control output | Transistor output | NPN | PNP | NPN | PNP | ||
Wiring | Direct outlet,DC2 wire,φ5,2*0.3 mm2,standard wire length: 2m; H3 model is connector type | Direct outlet,DC3 wire,φ5,3*0.3 mm2,standard wire length: 2m; H3 model is connector type | |||||
Protection rating | IP67 | ||||||
Work temperature | -25℃~75℃ (without freezing ) 35~95% RH | ||||||
Dimensions | Please check the dimension drawing | Please check the dimension drawing | |||||
Proximity sensor | |||||||
Model | IM18B-08-NO | IM18N-12-NO | IM18B-05-AO | IM18N-08-AO | IM18B-05-DO-H3 | IM18N-08-DO-H3 | |
General parameters: | |||||||
Installation method | Flush style | Non-flush | Flush style | Non-flush | Flush style | Non-flush | |
Detection distance | 8mm±10% | 12mm±10% | 5mm±10% | 8mm±10% | 5mm±10% | 8mm±10% | |
Return difference | ≤15% | ||||||
Set distance | 0~6.4mm | 0~9.6mm | 0~4 mm | 0~6.4 mm | 0~4mm | 0~6.4 mm | |
Mechanical/Electronic Parameters: | |||||||
Operating voltage | 10-30VDC | 24-240V AC | 10-30VDC | ||||
No-load current | Max.5mA |
| |||||
Voltage drop | Max.1.3V | Max.8V | Max.2.5V | ||||
Operating frequency | 300Hz | 150Hz | 20Hz | 350Hz | 200Hz | ||
Indicator light | Operation indicator yellow | ||||||
Function | Short circuit protection,over voltage protection,reverse polarity protection | over voltage protection | Short circuit protection,over voltage protection,reverse polarity protection | ||||
Action mode | Normally open | Normally closed (AC)/Normally open(AO) depending on the specific model | Normally closed (DC)/Normally open(DO) depending on the specific model | ||||
Control output | Transistor output | Single-stage SCR output | Transistor output | ||||
Wiring | Direct outlet,DC3 wire,φ5,3*0.3 mm2,standard wire length: 2m | Direct outlet,AC2 wire,φ5,3*0.3 mm2,standard wire length: 2m; | DC2 wire, Connector outlet,PL01、PL02、PL03 optional,standard wire length: 2m | ||||
Protection rating | IP67 | ||||||
Work temperature | -25℃~75℃ (without freezing ) 35~95% RH | ||||||
Dimensions | Please check the dimension drawing | Please check the dimension drawing | |||||