Welcome Customer !

Membership

南京宏沐科技有限公司
Free Member ·1YRS
,
Other

Main Products: 传感器

Xwboo>Products
Product Categories

南京宏沐科技有限公司Free·1YRS

  • E-mail

    hmsensor@163.com

  • Phone

    800-828-9705

  • Address

    Nanjint city jiangning shuangnong street number 568 taixing square 1-1302

Contact Now

HM29 Digital • Intellectual Pressure / Differential Pressure Transducer

Model
Nature of the Manufacturer
Other
Product Category
Press
Place of Origin
City, Province
Overview
HM29 digital • intellectual pressure / differential pressure transducer is a high – accuracy digital and intellectual product developed by German HELM to meet the market needs of Chinese mainland. This series of product adopt German HELM made sensor chip with highest performance and are designed incorporating with monolithic computer technology and sensor digital conversion technology, of which core component adopts 24–bit AD MCU micro – processor to ensure high quality of the transducer relying on its strong funct......
Product Details

Features of Product

☆ Baud rate from 1200 to 230400 bps

☆Overall accuracy up to ± 0.05% FS under special condition

☆ Optional many kinds of pressure unit, may be user – defined

☆ Sampling rate form 10 points / second to 1 point / 50 minutes

☆ RS 485 universal serial bus (USB) loop may connected with 63 sensor, as a maximal

☆ Communication with the computer via control software in Chinese as well as USB, RS - 232 / 485 port, with easy operation☆ Provided with micro – processor for digital compensation, control, and communication

☆ USB, RS - 232 / 485 port directly connecting with the computer

Application of Product

☆ 20 – bit effective resolution

☆ Absolute pressure, gauge pressure, and differential pressure

☆ Zero point and FS output setting

☆ Readable temperature value of the medium to be measured

Details


☆ National defense scientific research

☆ Scientific research and laboratory calibration

☆ Nuclear power generation and chemical

☆ Petroleum survey and investigation

☆ Military

☆ High – end equipment accessories

☆ Airspace and aerospace

☆ Support for engineering projects

Technical Data 

Measuring range

-100kPa ~ 0 ~ 5KPa … 100MPa

Overloading capacity

Two times of FS pressure (where over pressure for 100MPa is designed with 1.1 times of FS pressure)

Pressure type

Gauge pressure or absolute pressure

Medium to be measured

The gas or liquid compatible with 316 stainless steel

Overall accuracy
(Non-linear, repeatability, lagging)

± 0.05% FS

± 0.075% FS

± 0.1% FS

± 0.25% FS

Long-term stability

Typical: ± 0.1% FS / year

Maximum: ± 0.2% FS / year

Zero point temperature drifting

Typical: ± 0.005% FS

Maximum: ± 0.01% FS / ℃

Sensitivity temperature drifting

Typical: ± 0.005% FS

Maximum: ± 0.01% FS / ℃

Range of operating temperature

-40 ~ +85 ℃

Range of compensating temperature

-10 ~ +60 ℃

Range of power supplying

5 ~ 9V DC

Digital output

RS485 / USB / RS232

Baud rate

1200 , 2400 , 9600 , 19200 , 28800 , 57600 , 115200 , 230400

Data format

1–bit start bit, 8–bit data bit, 1–bit stop bit

Odd and even calibration

None

Sampling rate

10 points / second – 1 point / 50 minutes

Resolution

20 bit 10ppm

Product selection

HM28

Digital · Intellectual Pressure / Differential Pressure Transducer

Guideline of Selection

Digital · Intellectual Pressure / Differential Pressure Transducer

Code

Type of pressure

G

Gauge pressure ( may not be indicated)

A

Absolute pressure

D

Differential

Range

Measuring Range

0 ~ X KPa or 0 ~ X MPa

Code

Overall accuracy (linear + repeatability + lagging)

1

± 0.25% FS

2

± 0.1% FS

3

± 0.1% FS

4

± 0.075% FS

3

± 0.05% FS

 

Code

Signal Output Method

 

S1

RS 458

 

S2

RS 232

 

S3

USB

 

 

Code 

Additional functions

 

 

F1

M20 x 1.5 external thread

 

 

F2

G 1 / 4 external thread

 

 

F0

Special

 

 

W1

Cable type (IP67, 2m)

 

 

W2

Socket type (IP65, DIN 43650)

 

 

P

Flushed membrane type

 

 

E

Intrinsically safe explosion - proof type Ex ia II CT5

 

 

 

 

 

 

 

 

HM29 9( 0 ~ 100KPa)

— 4

— S1

— F1

— W1 Digital · Intellectual Pressure / Differential Pressure Transducer


Tips of Selection

  1. The medium to be measured shall be compatible with the material contacting with the product.
  2. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
  3. Please contact us in case of the other special requirements and clearly indicate them when placing an order.