HM70 Hygienic Flat - membrane Pressure Transducer

Model
Nature of the Manufacturer
Other
Product Category
Press
Place of Origin
City, Province
Overview
HM70 hygienic flat - membrane pressure transducer adopts imported high – accuracy and high – stability pressure sensor set to the absolute pressure or the gauge pressure of the medium to be measured into 4 ~ 20mA, 1 ~ 5V / 0 ~ 5V standard electrical signal through high – reliability amplification circuit and precise temperature compensation. High – quality sensor, fully – enclosed welded encapsulated technology as well as improved assembling process ensure superior quality and best performance of this series of pro......
Product Details

Features of Product

☆ High stability and high sensitivity

☆ Lightning and radio frequency disturbance immunity

☆ Diversified signal output form and adjustable zero point and full scale

☆ Reverse pole protection and transient over – current and over – voltage protection☆ Fully made of stainless steel

☆ Clean flat type of isolating membrane

Application of Product

☆ Hygienic pressure pipelines

☆ Food and beverage processing

☆ Medical and pharmaceutical

☆ Sewage treatment

☆ Viscous medium pressure measurement

Details

Technical Data 

HM70 Hygienic Flat - membrane Pressure Transducer

Medium to be measured

The liquid, gas or vapor compatible with 316 stainless steel

Measuring range

-100kPa ~ 0 ~ 20KPa … 35MPa

Overloading capacity

1.5 times of FS pressure

Pressure type

Gauge pressure or absolute pressure

Overall accuracy
(Non-linear, repeatability, lagging)

Typical: ± 0.25% FS

Maximum: ± 0.4% FS

Long-term stability

Typical: ± 0.1% FS / year

Maximum: ± 0.2% FS / year

Zero point temperature drifting

Typical: ± 0.02% FS / ℃

Maximum: ± 0.03% FS / ℃

Sensitivity temperature drifting

Typical: ± 0.02% FS / ℃

Maximum: ± 0.03% FS / ℃

Medium temperature

-20 ~ +85 ℃

Compensating temperature

-10 ~ +50 ℃

Ambient temperature

-20 ~ +80 ℃

Range of power supplying

12 ~ 36V DC (24V DC generally)

Signal output

4 ~ 20mA / 1 ~ 5V DC / 0 ~ 5V DC / 0.5 ~ 4.5V DC

Load resistance

≤ (U-12) / 0.02Ω

Enclosure protective degree

Plug type (IP 67); Cable type (IP 65)

Thermal lagging

± 0.02% (typical)

Process connection

M30 x 1.5 external thread or clamp

Safe explosion – proof

Ex ia II CT5

Weight

Approx. 0.5kg

Response time

≤2 ms

Insulation resistance

100MΩ 500V DC

Product selection

HM70

Hygienic Flat - membrane Pressure Transducer

Guideline of Selection

Type of pressure

Gauge pressure ( G, may not be indicated), Absolute pressure (A)

Range

Measuring Range

(0 ~ X KPa or 0 ~ X MPa

Code

Overall accuracy (linear + repeatability + lagging)

1

± 0.4% FS

2

± 0.25% FS

3

± 0.1% FS

 

Code

Signal Output

 

A1

4 ~ 20mA

 

V1

1 ~ 5V DC

 

V2

0 ~ 5V DC

 

V3

0.5 ~ 4.5V DC

 

 

Code 

Additional functions

 

 

F1

M30 x 1.5 external thread

 

 

F2

Clamp type

 

 

F0

Special

 

 

W1

Cable type (IP67, 2m)

 

 

W2

Socket type (IP65, DIN 43650)

 

 

E

Intrinsically safe explosion - proof type Ex ia II CT5

 

 

 

 

 

 

 

 

HM70 (0 ~ 100KPa

— 1

— A1

— F1

— W2 Hygienic Flat - membrane Pressure Transducer

Tips of Selection

  1. Correctly adopt sealing means to prevent the product stability from influencing due to installing stress when the flushed membrane product is installed on site.
  2. The medium to be measured shall be compatible with the material contacting with the product.
  3. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
  4. Please contact us in case of the other special requirements and clearly indicate them when placing an order.