JLA250V3AB-35D1-W Power filter
Features
--On the basis of GJB6242-2008 standard production, working temperature -55 ℃ ~ + 85 ℃.
--A two-stage filter circuit is designed for military equipment,to ensure it can through the requirements of CE102 in GJB151A / 152B.
--Can meet the different current, voltage, and fast customization.
Electrical schematic
Rule of Nomination
| JLA | 250V | 1A | B | - | 35 | D1 | - | Q |
| | | | |
|
| | | | |
| | |
| voltage
| current
|
| - | circuit
| shell
| - | optional
|
Tabulates
| Model No. | Rated Current @40°C
| Terminal Options*
| Leakage current 250V/50Hz | Electrical Schematic | Rated Voltage (V) | Operating Frequency (Hz) |
|
| | | |
| JLA250V1AB-35D1 | 1A | - | - | W | <> | Fig.1 | 115/250V | 50/60Hz |
| JLA250V3AB-35D1 | 3A | - | - | W | Fig.1 |
| JLA250V6AB-35D3 | 6A | Q | S | W | Fig.1 |
| JLA250V10AB-35D5 | 10A | Q | S | W | Fig.1 |
| JLA250V20AB-35D6 | 20A | Q | S | - | <> | Fig.1 |
| JLA250V30AB-42F2 | 30A | Q | S | - | Fig.2 |
| JLA250V50AB-42F3 | 50A | Q | S | - | <> | Fig.2 |
| JLA250V100AB-42F6 | 100A | Q | S | - | Fig.2 |
Mechanical Dimension
Insertion loss table(In 50ohm system according IEC/CISPR 7)
| -------common mode | -------differential mode |