Fix the appliance on the wall at a horizontal distance as 2~4m from the cooker or gas source;
The vertical location of the appliance should be decided according to the type of gas sort:
●LPG:Fix it within 0.3 meters above the ground;
●Natural Gas:Fix it within 0.3 meters below the Roof
Such location should be avoided:
◆Near the windows or passage with strong wind,
◆Water fog and drop or such moist place;
◆Easy polluted or high tem environment near Oven,
◆Covered by other things.
| Model | BH-H3 |
| Detecting gas | Combustible gas & CO |
| Sensor type | Semiconductor sensor |
| Gas Sampling | Diffuse naturally |
| Alarm set point | Combustible gas: 10%LEL / CO: 100PPM |
| Warming time | 3min |
| Accuracy | Combustible gas: ±3%LEL / CO: ±50PPM |
| Response time | ≦60s |
| Resume automatically | ≦30s |
| Power | AC220V |
| Alarm current | <50mA |
| Power Consumption | <1W |
| Alarm Method | Visual and audible |
| Sound level | ≧70dB |
| Optional function | 220V relay,9V pulse, relay output NO or NC |
| Environment | Temperature: 0℃~55℃ Humidity: <95% no dew |
| Life | 5 year (normal use) |
| Weight | 150g |
| Dimension | L×B×H(mm):108×82×49.5 |
TAG:   Gas Domestic Alarm Gas Detector For Home Gas Alarm  home co detector gas detector oem