Electronic flow switch
Product Details

VHS series of electronic flow switch Features:

1, the probe after special treatment, the outer surface of a protective film, completely anti-corrosion, anti-scaling;
2, Driven directly by the drive screw potentiometer settings, without disassembly, so completely waterproof
3, using the original double adjustment technology, more convenient adjustment, showing more accurate
4, LED lights can reflect the size of the current traffic
5, ultra-small shell, integrated design, all made of stainless steel, practical and beautiful
6, the interface uses a standard interface, fully compatible with other common products, you can directly replace
7, can completely replace the commonly used monotonic thermal conductivity, is a single thermal conductivity of the upgrading of products

VHS series of electronic flow switch overview

At present, with the continuous development of electronic technology, thermal flow switch has been widely used in measuring all walks of life, will gradually replace the traditional mechanical flow switch. However, many problems occur when the design is improper or the materials and components are not selected properly. The problems that often occur are as follows:
1, the thermal flow switch is detected by the principle of heat conduction the size of the flow, will inevitably generate heat, heat is too small, the measurement range is limited, too much heat will often appear as a result of overheating products burned partially and can not work phenomenon.
2, the traditional thermal flow switch is only one adjustment potentiometer, only the action point set, if there is no flow in the case of regulation, when there may be traffic flow switch or detect no flow, the relay can not move; and If there is traffic in the case of regulation, it may be no flow, the flow switch still detects the flow, the relay can not be reset, so you need to repeatedly adjust to meet the field requirements, neither convenient nor accurate, and often The adjusted action point will change after a period of time and needs to be readjusted.
3, the ordinary flow switch in the adjustment of the operating point, we must first remove the protective screw on the panel to be adjusted, so that when the protective screw is missing or spin tight, the external environment of the condensate along the protective screw Into the product, resulting in damage to the product.
4, the ordinary flow switch Although there are several green lights can be used to indicate the size of the traffic, but because the scene can not be calibrated, often when the traffic is full of light, no traffic when the whole off, so that several green light on and off It can only indicate the presence or absence of traffic, but simply can not reflect the size of the traffic, the number of green light off no sense at all.
VHS20 series dual modulation flow control switch is developed specifically for the current thermal flow switch problems developed by a thermal flow switch, you can completely solve the current common single-regulation thermal flow switch has many problems, is a common monotonic Thermal flow switch upgrade alternative products, will completely replace the ordinary single-regulation thermal flow switch, is particularly suitable for ordinary single-regulation thermal flow switch can not be measured normally.

VHS series of electronic flow switch technical parameters

1, setting mode: two potentiometer settings (no disassembly, driven directly by the drive screw potentiometer settings), a set point of action, a set range
2, measuring range: water 0-10m / s, oil 0-15 m / s, gas: 0 ~ 30 m / s
3, working voltage: DC24V, AC / DC110V, AC / DC220V
4, the working current: <60mA
5, the output mode: relay output, PNP output, NPN output
6, response time: 1 ~ 10S, typical 2S
7, initialization time: about 8S
8, electrical protection: reverse phase, short circuit, overload protection

9, contact capacity: 1A / 125VAC, 2A / 30VDC
10, Insulation resistance: 100MΩ / 500VDC
11, pressure range: 100bar
12, medium temperature: conventional -20 ~ 80 ℃, high temperature 0-150 ℃
13, shell material: 304 stainless steel
14, probe material: 316 stainless steel
15, interface size: the default G1 / 2
16, protection class: IP67