1.FEATURES
◆Excellent long term stability (4 ~ 20mA, 500 )
◆Precision measurement even for unbalance system
◆Precision measurement even for distorted wave
◆ High impulse & surge protection (5KV)
◆The case can be mounted on a 35mm rail which complies with DIN 46277
2.DESCRIPTION
Model:
S3-WRD-1 1φ2W, Accuracy:± 0.2% RO.
S3-WRD-3 3φ3W, Accuracy:± 0.2% RO.
S3-WRD-3A 3φ4W, Accuracy:± 0.2% RO.
N3-WRD-1 1φ2W, Accuracy:± 0.5% RO.
N3-WRD-3 3φ3W, Accuracy:± 0.5% RO.
N3-WRD-3A 3φ4W, Accuracy:± 0.5% RO.
A wide range of transducers to measure all forms of WATT, VAR, in both balanced and unbalanced, single or 3 phase system. They utilize the well prove "time division multiplication" method of measuring instantaneous power over a wide range of input waveforms. The circuit diagram shown measured voltage is modulated by circuit of an oscillator. Square wave pulses from a multi-vibrator circuit, with a mark.- space ratio varied by the measured voltage and amplitued by the measured current, are fed to an integrator an output amplification circuit. The dc signal produced is then directly proportional to power input - Watt & Vars.
3.SPECIFICATION:
3.1 INPUT:
Input Range | Max. Input Over Capability |
Circuit | Amp. | Voltage | Basic W | Basic Var |
Single Phase | 5 A | 110V (120V) | ± 0.5KW | ± 0.5KVar | Ampere: 3 x rated continuous 10 x rated 10 sec. 50 x rated 1 sec. Voltage: 2 x rated continuous |
220V (240V) | ± 1KW | ± 1KVar |
3-Phase 3-Wire | 5 A | 110V (120V) | ± 1KW | ± 1KVar |
220V (240V) | ± 2KW | ± 2KVar |
3-Phase 4-Wire | 5 A | 190V/110V (208/120V) | ± 1.5KW | ±1.5KVar |
380V/220V (416/240V) | ± 3KW | ± 3KVar |
3.2 OUTPUT:
DC Output Range | Load Resistance | Output Resistance | Output Ripple | Response Time |
-1 ~ 0 ~ 1V | 1K | ≤0.05W | ≤ 0.5% RO. (Peak) | ≤400mS. 0 ~ 99% |
-5 ~ 0 ~ 5V |
1 ~ 3 ~ 5V |
0 ~ 5 ~ 10V |
-1 ~ 0 ~ 1mA | 0 ~ 10K | 20MW |
-10 ~ 0 ~ 10mA | 0 ~ 1K | 5MW |
0 ~10 ~ 20mA | 0~500 W |
4 ~12 ~ 20mA |
4.Specification:
Aux. power supply | AC 110V ± 15%, 50/60HZ AC 220V ± 15%, 50/60HZ DC24V, 48V, 110V, ± 15% |
Power consumption | -2.5VA, ≤DC 3W |
Power effect | ≤0.1% RO |
Waveform effect | ≤0.2% RO. at distortion factor 30%( PCIR) |
Output load effect | ≤0.05% RO. |
Magnetic field strength | -0.2% RO., 400A/M |
Span adjustment range | 5%RO |
Zero adjustment range | 1%RO |
Operating temperature range | 0 ~ 60℃ |
Operating temperature range | 0 ~ 60℃ |
Storage temperature range | -10 ~ 70℃ |
Temperature coefficient | - 100PPM from 0 to 60℃ ≤ 60PPM, 25。C ± 10℃ |
Max. relative humidity | 95% |
Isolation | Input/output/power/case |
Insulation resistance | 100M W, DC 500V |
Dielectric withstand voltage | Between input/output/power/case (IEC 414, 688,ANSI, C37) AC 2.6KV, 60HZ, 1 min. |
Impulse withstand test | 5KV, 1.2 X 50μS (IEC 255-4, ANSI C37 90a) Common mode & differential mod |
Performance | Designed to comply with IEC688 |
Safety requirements | IEC 414, BS5458 |
5.Trminal Connection:
5.1 S3-WD-1, N3-PD-1 (1φ2W):
5.2 S3-PD-3, N3-PD-3 (3φ3W)
6.THE OUTSIDE DIMENSION (UNIT:mm)
7.PANEL MOUNTING HOLES (UNIT:mm)