2. Example of model and parameter filling:
(1) S3-PD-3-555A4B
0.5%RO, 3φ3W power factor transducer
Input nominal current: 5A;
Input nominal voltage: 100V;
Input signal frequency: 50±5Hz;
Output range: 4~12~20mA;
Correspond to -0.5 (capacity) ~1~0.5 (inductive);
Auxiliary power supply: AC220V.
(2) S3-PD-3A-165A5B
0.5%RO, 3φ3W system power factor transducer
Input nominal current: 1A;
Input nominal voltage: 57.7V;
Input signal frequency: 50±5Hz;
Output range: -20~0~20mA;
Correspond to -0.5 (capacity) ~1~0.5 (inductive);
Auxiliary power supply: AC220V.
Note:
1 If the user needs other special calibration, please indicate the parameter value in the contract.
2 power factor input, output value conversion:
y = a1cosф+b1(ф:0 to 60°)
y = a2cosф+b2(ф:0~-60°)
In the above formula: y is the output of the power factor transducer, and y, a, b should be selected according to the different output modes of the powe