1. Model:
S3-RD-1 : 1φ2W reactive power transducer, accuracy : 0.2% RO
S3-RD-1S : 1φ2W reactive power transducer, accuracy : 0.2% RO, (dual output)
S3-RD-3 : 3φ3W reactive power transducer, accuracy : 0.2% RO
S3-RD-3S : 3φ3W reactive power transducer, accuracy : 0.2% RO (dual output)
S3-RD-3A : 3φ4W reactive power transducer, accuracy : 0.2% RO
S3-RD-3AS: 3φ4W reactive power transducer, accuracy : 0.2% RO (dual output)
N3-RD-1 : 1φ2W reactive power transducer, accuracy : 0.5% RO
N3-RD-1S : 1φ2W reactive power transducer, accuracy : 0.5% RO, (dual output)
N3-RD-3 : 3φ3W reactive power transducer, accuracy : 0.5% RO
N3-RD-3S : 3φ3W reactive power transducer, accuracy : 0.5% RO (dual output)
N3-RD-3A : 3φ4W reactive power transducer, accuracy : 0.5% RO
N3-RD-3AS: 3φ4W reactive power transducer, accuracy : 0.5% RO (dual output)
2.Order form:

3. Example of model and parameter filling:
(1) N3-RD-3-555A4BY
0.5%RO, 3φ3W reactive power transducer (cross-phase)
Input nominal current: 5A; input nominal voltage: 100V;
Nominal input power 4: 866W;
Input signal frequency: 50±5Hz;
Output range: 4~12~20mA;
Correspondence -866~0~866Var
Auxiliary power supply: AC220V. Need to measure the reverse power.
(2) S3-RD-3T-155V2BY
0.2%RO,3φ3W reactive power transducer (phase shift method)
Input nominal current: 1A; input nominal voltage: 100V;
Nominal input power 4:170W;
Input signal frequency: 50±5Hz;
Output range: -5~0~5V;
Correspond to -170~0~170Var
Auxiliary power supply: AC220V. Need to measure the reverse power.
(3) S3-RD-3AT-565A4BN
0.5%RO 3φ4W reactive power transducer (phase shift)
Input nominal current: 5A; input nominal voltage: 57.7V;
Nominal input power 4: 866W;
Input signal frequency: 50±5Hz;
Output range: 4~20mA;
Corresponding 0~866Var
Auxiliary power supply: AC220V. There is no need to measure reverse power.
Note:
1 system: T mark, measured by phase shift method; no T mark, measured by cross-phase method.
The output of the 2 dual output channels is 1 (+) and 2 (-) terminals.
3 The value in the output range () is the value specified when the forward and reverse power are output. For reactive power measurement: when the negative value is output, it means that the capacitive impedance of the system is the largest; when the positive value is output, it means that the inductive impedance of the system is the largest.
4 calibration of system power see the previous active power note: 2 items.
5 If the user needs other special calibration, please indicate the parameter value in the contract.