1.Introduction:
FPWH type active energy transmitter, FPKH type reactive energy transmitter is an instrument for measuring active and reactive energy, FPWWH type active power / active energy, FPKKH type reactive power / reactive power combined transmitter It is a dual-function instrument that can measure both active (or reactive) power and active (or reactive) power. It is an auxiliary instrument for energy metering, energy-saving automation and computer electricity billing.
FP series electric energy transmitter technical indicators fully comply with the requirements of JJG 596-89 "Electronic energy meter", the relative error is less than 0.5%, and has excellent temperature characteristics and long-term stability, coupled with electric energy display recording device, can be used In the grid dispatching system, it is also an ideal solid-state electric energy meter.
The transmitter is suitable for single-phase, three-phase (balanced load and unbalanced load) lines with frequency of 50Hz, 60Hz and special frequency. The electric energy is pulsed output with two types of optocoupler open collector or relay contact to adapt to different RTU and power recording device. The digital output corresponds to the active (or reactive) energy measured by the input. The output lead is four wires, and the bidirectional digital output outputs electrical energy in both positive and negative directions.
Main models:
FPWH201 3 phase 3 wires WattHour
FPKH201 3 phase 3 wires VarHour
FPWH301 3 phase 4 wires WattHour
FPKH301 3 phase 4 wires VarHour
FPWWH201 3 phase 3 wires Watt & WattHour
FPKKH201 3 phase 3 wires Var & VarHour
FPWWH301 3 phase 4 wires Watt & WattHour
FPKKH301 3 phase 4 wires Var & VarHour
2.Specification
Accuracy ( 23±3℃) : | | 0.2% reading / PF ± 0.05% RO |
Maximum output load: | | DC current mode : maximum 10V drop DC voltage mode : maximum 5mA drive |
Dielectric strength | | AC 2KV 1 minute between terminals AC 2.6KV 1 minute / terminals to case |
Output of WH & VarH | | Open collecter type, maximum 30V / 30mA |
Surge and impulse test | | ANSI C37.90 / 1989,IEC 255-3 (1989) 4 KV 1.2 x 50 us |
Maximum input over | | Current related input | Voltage related input |
| 1A / 5A | 10A | |
| 4 x rated / continuous | 2 x rated / continuous | 1.5 x rated / continuous |
| 10 x rated / 10 seconds | 25 x rated / 1 second | 2 x rated / 10 seconds |
| 50 x rated / 1 second | 50 x rated / 0.5 second | |
| 80 x rated / 0.5 second | | |
Input burden | | Current less 0.2 VA; voltage less 0.1 VA |
Response time & ripple | | ≤400 ms for step change 0-99% ripple less 0.5% ro peak to peak |
Frequency | | 50 ± 2 Hz; 60 ± 2 Hz; 400 ± 5 Hz ( Watt only ) |
Waveform | | Watt :- 2% 3rd, Var: - sinusoidal |
Stability | | Temperature range ( 20 to 26℃), long term stability / year Maximum 70 ppm /℃, less 0.2% draft / year typically |
Storage condition | | Temperature range -25 to 70℃, RH 20 to 95% non condensed |
Operating condition | | Temperature range -20 to 65°C, RH 0 to 99% non condensed |
Magnetic field effect | | < 0.01% under 100 ampere turns at 1M center |
Power dissipation | | < 7 VA
|
3.Outline dimension

4.Terminal Connection: