R410a DC Inverter Series

Model
Nature of the Manufacturer
Manufacturer
Product Category
EVI Inverter Heat Pump System
Place of Origin
City, Province
Overview
R410a DC Inverter Series
Product Details

Get Class A++ energy label based on EN14825 standard.




Inverter Heat Pump





EVI technology can work in-30degrees





Inverter Heat Pump




With Heating/cooling/ hot water function




Inverter Heat Pump



Significantly reduced running costs(up to 50% saving)compared to non-inverter systems



Inverter Heat Pump



Improved comfort as set-point temperatures are achieved more quickly




Inverter Heat Pump




Operating at air temperature-30-+43C, all year round running



Inverter Heat Pump


Low noise owing to the axial fan and compressor unit with variable operating frequency



Inverter Heat Pump

Product model PF-030DC/E PF-050DC/E PF-050DC/NE
Cooling Cooling capacity(kW) 7.7 12.8 12.8
Cooling capacity Min / Max(kW) 4.9/8.9 8.2/14.8 8.2/14.8
Cooling input power(kW) 2.6 4.2 4.2
Cooling input power Min / Max (kW) 1.5/3.7 2.5/6.0 2.5/6.0
Rated current (A) 12.7 20.5 8.4
Current Min / Max (A) 7.3/18.1 12.2/29.3 5.0/12.0
EER 2.96 3.05 3.05
EER Min / Max 2.41/3.27 2.47/3.28 2.47/3.28
Heating Heating capacity(kW) 11.8 18.8 18.8
Heating capacity Min / Max (kW) 7.4/15.9 11.7/23.5 11.7/23.5
Heating input power(kW) 2.64 4.2 4.2
Heating input power Min / Max (kW) 1.5/3.9 2.4/6.4 2.4/6.4
Rated current (A) 12.8 21 8.4
Current Min / Max (A) 7.5/19.3 11.7/30.5 4.8/12.8
COP 4.47 4.48 4.48
COP Min / Max 3.69/4.9 3.67/4.88 3.67/4.88
DHW Heating capacity(kW) 9.5 15.4 15.4
Heating capacity Min / Max (kW) 5.9/12.8 9.4/19.8 9.4/19.8
Heating input power(kW) 2.7 4.4 4.4
Heating input power Min / Max (kW) 1.5/4.2 2.4/6.8 2.4/6.8
Rated current (A) 13 22 8.8
Current Min / Max (A) 7.3/19.7 12.1/32.8 4.8/13.6
COP 3.52 3.50 3.50
COP Min / Max 3.05/3.93 2.91/3.92 2.91/3.92
Refrigerant R410A
Power supply 208~240V~/50Hz 380~415V/3N~/50Hz
Working area -30~43℃
Water circulation (m³/H) 2.03 3.23 3.23
Water pressure drop (kPa) 25 30 30
IP Grade (Level of protection) IPX4 IPX4 IPX4
Anti-electric shock Rate I I I
Noise (dB(A)) ≤53 ≤58 ≤58
Net weight/Gross weight(kg) 110/120 145/155 145/155
Diameter of pipe (mm) DN25 DN25 DN25
Body size(W*D*H) 1115*425*710 1050*480*1330 1050*480*1330
Packing size(W*D*H) 110*510*1080 1120*530*1450 1120*530*1450
Loading quantity (20GP/40GP/40HQ) 48/100/150 18/42/42 18/42/42
Remark: Cooling working condition:Inlet water temperature 12℃, Outlet water temperature 7℃, Dry bulb temperature 35℃, Wet bulb temperature 24℃.
Heating working condition: Inlet water temperature 30℃, Outlet water temperature 35℃, Dry bulb temperature 7℃, Wet bulb temperature6℃.
DHW working condition: Inlet water temperature 15℃, Outlet water temperature 55℃, Dry bulb temperature 7℃, Wet bulb temperature 6℃.

Product model PF-030DC/E PF-050DC/E PF-050DC/NE
Cooling Cooling capacity(kW) 7.7 12.8 12.8
Cooling capacity Min / Max(kW) 4.9/8.9 8.2/14.8 8.2/14.8
Cooling input power(kW) 2.6 4.2 4.2
Cooling input power Min / Max (kW) 1.5/3.7 2.5/6.0 2.5/6.0
Rated current (A) 12.7 20.5 8.4
Current Min / Max (A) 7.3/18.1 12.2/29.3 5.0/12.0
EER 2.96 3.05 3.05
EER Min / Max 2.41/3.27 2.47/3.28 2.47/3.28
Heating Heating capacity(kW) 11.8 18.8 18.8
Heating capacity Min / Max (kW) 7.4/15.9 11.7/23.5 11.7/23.5
Heating input power(kW) 2.64 4.2 4.2
Heating input power Min / Max (kW) 1.5/3.9 2.4/6.4 2.4/6.4
Rated current (A) 12.8 21 8.4
Current Min / Max (A) 7.5/19.3 11.7/30.5 4.8/12.8
COP 4.47 4.48 4.48
COP Min / Max 3.69/4.9 3.67/4.88 3.67/4.88
DHW Heating capacity(kW) 9.5 15.4 15.4
Heating capacity Min / Max (kW) 5.9/12.8 9.4/19.8 9.4/19.8
Heating input power(kW) 2.7 4.4 4.4
Heating input power Min / Max (kW) 1.5/4.2 2.4/6.8 2.4/6.8
Rated current (A) 13 22 8.8
Current Min / Max (A) 7.3/19.7 12.1/32.8 4.8/13.6
COP 3.52 3.50 3.50
COP Min / Max 3.05/3.93 2.91/3.92 2.91/3.92
Refrigerant R410A
Power supply 208~240V~/50Hz 380~415V/3N~/50Hz
Working area -30~43℃
Water circulation (m³/H) 2.03 3.23 3.23
Water pressure drop (kPa) 25 30 30
IP Grade (Level of protection) IPX4 IPX4 IPX4
Anti-electric shock Rate I I I
Noise (dB(A)) ≤53 ≤58 ≤58
Net weight/Gross weight(kg) 110/120 145/155 145/155
Diameter of pipe (mm) DN25 DN25 DN25
Body size(W*D*H) 1115*425*710 1050*480*1330 1050*480*1330
Packing size(W*D*H) 110*510*1080 1120*530*1450 1120*530*1450
Loading quantity (20GP/40GP/40HQ) 48/100/150 18/42/42 18/42/42
Remark: Cooling working condition:Inlet water temperature 12℃, Outlet water temperature 7℃, Dry bulb temperature 35℃, Wet bulb temperature 24℃.
Heating working condition: Inlet water temperature 30℃, Outlet water temperature 35℃, Dry bulb temperature 7℃, Wet bulb temperature6℃.
DHW working condition: Inlet water temperature 15℃, Outlet water temperature 55℃, Dry bulb temperature 7℃, Wet bulb temperature 6℃.