LCD display MPPT solar charge controller
Untra-fast
Maximum Power Point Tracking(MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an
ultra fast MPPT controller will improve energy harvest by up to
30%
compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers
Load output
Over-discharge of the battery can be prevented by connecting all loads to the load
output. The load outputwill disconnect the load when the battery has
been discharged to a pre-set voltage
Alternatively, an intelligent battery management algorithm can be chosen: see Battery Life
The load output is short circuit proof
Some loads (especially inverters) can best be connected directly to the battery, and the
inverter remotecontrol connected to the load output. A special
interface cable may be needed, please see the manual
Battery Life.
intelligent battery management
When a solar charge controller is not able to recharge the battery to its full capacity
within one day, the result is often that the battery will continually be cycled between a
partially charged state and the 'end of discharge' state. This mode of operation (no
regular full recharge) will destroy a lead-acid battery within weeks or months
The Battery Life algorithm will monitor the state of charge of the battery and, if needed
day by day slightlyincrease the load disconnect level (i. e. disconnect the load earlier
until the harvested solar energy issufficient to recharge the battery to nearly the ful
99%. From that point onwards the load
disconnect level will be modulated so that a nearly 99% recharge is achieved about once every week
Programmable battery charge algorithm
Day/night timing and light dimming option
Only factory setting
Display
Graphical lCd display
Operation
Simple menu-driven operation
Programming by buttons
Certificates
■Compliant with European Standards(CE)
■ ROHS compliant
■SGS
■|So9001
■ Made in China
Maximum Power Point Tracking
Upper curve
Output current o of a solar panel as function of output voltage(V)
■The maximum power point(MPP)is the point
Pmax along the curve where the product x V reaches its peak
Lower curve:
■Output power P=l as function of output voltage.
When using a PWM(not MPPT) controller the output voltage of the solar panel will be
nearly equal to the voltage of the battery, and will belower than Vmp.
Solar Charge Controller | MPPT 100/15D |
System voltage | 12/24 V Auto Select |
Maximum output current | 15A |
Maximum PV power, 12V 1a, b) | 200W |
Maximum PV power, 24V 1a, b) | 400W |
Maximum PV open circuit voltage | 100v |
Maximum efficiency | 98% |
Self-consumption | 20 mA |
Charge voltage ‘absorption’ | Default setting: 14, 4 V/28.8 V(adjustable) |
Charge voltage ‘float’ | Default setting: 13, 8 V/27, 6V( adjustable) |
Charge algorithm | multi-stage adaptive |
Temperature compensation | -16mV/° C resp.-32mV/°C |
Continuous/peak load current | 15A50A |
Low voltage load disconnect | 11,1V/22,2or118V/23,6 or Battery life algorithm |
Low voltage load reconnect | 13, 1V/26,2V or 14V/28V or Battery Life |
Protection | Battery reverse polarity (fuse)/Outp ut short circuit /over temperature |
Operating temperature | 30 to +60℃ (full r ated output up to 40℃) |
Humidity | 95%, non-condensing |
ENCLOSURE |
Terminals(fine/single wire) | 6mm²/AWG10 |
Protection category | IIP22 (connection area) |
weight | 0.5kg |
Dimensions (X X Y x Z) | 136×98×55mm |
STANDARDS |
safety | EN/IEC 62109 |
1a) If more PV power is connected,the controller will limit input power to the stated maximum.
1b) PV voltage must exceed Vbat +5V for the controller to start. Thereafter minimum PV voltage is Vbat +1V.