Welcome Customer !

Membership

Wenzhou Xihe Electric Co.,LTD.
Free Member ·1YRS
WenZhou,ZheJiang
Manufacturer

Main Products: Solar charge controller

Xwboo>Products

New Power Star M Hybrid Inverter

Model
Nature of the Manufacturer
Manufacturer
Product Category
Off Grid Inverter
Place of Origin
City, Province
Overview
New Power Star M Hybrid Inverter
Product Details


Features and performances

 

▶ True sine wave voltage

▶ Reliable and silent with any kind of load

▶ Outstanding overload capabilities

▶ Smart-Boost function for assistance to the source even with difficult loads

▶ Automatic reduction of peak loads (power shaving)

▶ Multi-stage programmable battery charger with PFC (Power Factor Correction)

▶ Stand-by level adjustable over a large range and from a very low threshold

▶ Ultra-fast transfer relay

▶ Control by digital signal processors (DSP)

▶ High efficiency

▶ 2-year warranty

 

 

 

Model

PSM 1500-12

PSM  2000-12

PSM 2400-24

PSM 3500-24

PSM 2600-48

PSM  4000-48

Characterisation of the operating performance







Nominal battery voltage 

12V

12V

24V

24V

48V

48V

Input voltage range 

9.5-17VDC

9.5-17VDC

19-34VDC

19-34VDC

36-68VDC

36-68VDC

Continuous Power

1500VA

2000VA

2000VA

3000VA

2000VA

3500VA

Power 30 min.

1500VA

2000VA

2400VA

3500VA

2600VA

4000VA

Power 5 Sec.

3400VA

4800VA

6000VA

9000VA

6500VA

10500VA

Max.efficiency

93%

93%

94%

94%

96%

96%

Own consumption stand by 

1.4W

1.4W

1.6W

1.6W

2.0W

2.1W

Own consumption stand by 

8.0W

10W

9W

12W

10W

14W

Acoustic level without ventilation 

40 dB






Acoustic level with ventilation

45 dB






Maximum load

Up to short-circuit 






Maximum asymmetric load 

Up to Pcont.






Load detection (stand-by)

2 to 25 W






Cos φ

0.1-1






Output voltage

Pure sine wave 230Vac (±2%) / 120Vac (1)






Output frequency

45Hz-60Hz(1) ± 0.05% (crystal controlled)






Harmonic distortion

<2%






Overload and short-circuit protection

Automatic disconnection with 3 time restart attempt






Overheat protection

Warning before shut-off - with automatic restart






Battery charger







Charge Characteristic

6 steps : Bulk-Absorption-Floating-Equalization-reduced floating-periodic absorption Number of steps,thresholds,end current and times completely adjustable with the RCC-02/03






Temperature compensation

With BTS-01 or BSP 500/1200






Maximum charging current

70A

100A

55A

90A

30A

50A

Input voltage range 

150 to 265Vac / 50 to 140Vac (1)






Input frequency

45 to 65Hz






Input current max . (transfer relay) / Output current max .

50Aac / 56Aac






Transfer time 

< 15ms






Protection index

IP 20






Operating temperature range

-20 to 55ºC






Ventilation

Forced from 55ºC






Warranty 

2 Years






▶ Smart-Boost function for assistance to the source even with difficult loads

▶ Automatic reduction of peak loads (power shaving)

▶ Multi-stage programmable battery charger with PFC (Power Factor Correction)

▶ Stand-by level adjustable over a large range and from a very low threshold

▶ Ultra-fast transfer relay

▶ Control by digital signal processors (DSP)

▶ High efficiency

▶ 2-year warranty

 

 

 

Model

PSM 1500-12

PSM  2000-12

PSM 2400-24

PSM 3500-24

PSM 2600-48

PSM  4000-48

Characterisation of the operating performance

Nominal battery voltage 

12V

12V

24V

24V

48V

48V

Input voltage range 

9.5-17VDC

9.5-17VDC

19-34VDC

19-34VDC

36-68VDC

36-68VDC

Continuous Power

1500VA

2000VA

2000VA

3000VA

2000VA

3500VA

Power 30 min.

1500VA

2000VA

2400VA

3500VA

2600VA

4000VA

Power 5 Sec.

3400VA

4800VA

6000VA

9000VA

6500VA

10500VA

Max.efficiency

93%

93%

94%

94%

96%

96%

Own consumption stand by 

1.4W

1.4W

1.6W

1.6W

2.0W

2.1W

Own consumption stand by 

8.0W

10W

9W

12W

10W

14W

Acoustic level without ventilation 

40 dB

Acoustic level with ventilation

45 dB

Maximum load

Up to short-circuit 

Maximum asymmetric load 

Up to Pcont.

Load detection (stand-by)

2 to 25 W

Cos φ

0.1-1

Output voltage

Pure sine wave 230Vac (±2%) / 120Vac (1)

Output frequency

45Hz-60Hz(1) ± 0.05% (crystal controlled)

Harmonic distortion

<2%

Overload and short-circuit protection

Automatic disconnection with 3 time restart attempt

Overheat protection

Warning before shut-off - with automatic restart

Battery charger

Charge Characteristic

6 steps : Bulk-Absorption-Floating-Equalization-reduced floating-periodic absorption Number of steps,thresholds,end current and times completely adjustable with the RCC-02/03

Temperature compensation

With BTS-01 or BSP 500/1200

Maximum charging current

70A

100A

55A

90A

30A

50A

Input voltage range 

150 to 265Vac / 50 to 140Vac (1)

Input frequency

45 to 65Hz

Input current max . (transfer relay) / Output current max .

50Aac / 56Aac

Transfer time 

< 15ms

Protection index

IP 20

Operating temperature range

-20 to 55ºC

Ventilation

Forced from 55ºC

Warranty 

2 Years


Similar Product Recommend