Performance parameters |
| Pressure range | -100kPa…0~10kPa…10MPa |
|
| Pressure reference | Gauge pressure, absolute pressure, sealed gauge pressure |
|
| Supply & output | 4~20mA (12~30VDC) 0~5V, 1~5V, 0.5~4.5V, 0~10V (12~24VDC) |
|
| Accuracy | ±0.5%FS |
|
| Hysteresis & repeatability | 0.1%FS |
|
| Temperature drift | 1.5%FS (@-20℃~85℃) |
|
| Response time | ≤1ms (up to 90%FS) |
|
| Service life | ≥10×106 pressure cycles |
|
| Operating temp. | -20℃~85℃ |
|
| Storage temp. | -40℃~85℃ |
|
| Medium temp. | -40~85℃ (without cooling fans) -40~150℃ (with 3 cooling fans), -40℃~250℃ (with 5 cooling fans) |
|
| Insulation resistance | ≥100MΩ/250VDC |
|
| Vibration resistance | Sine curve: 20g, 25Hz~2kHz;IEC 60068-2-6 Random: 7.5grms, 5Hz~1kHz;IEC 60068-2-64 |
|
| Protection | IP65 |
|
| Medium compatibility | All the media compatible with stainless steel 316L |
|
| Ex-proof | ExiaⅡCT6 |
|
Different types of pressure trasducers: