Basic data of BMS Specification and test curve of battery cells Specification of battery cells Precautions The output voltage of the battery product has exceeded the safe voltage range that can be touched by the human body. Please protect it during installation and use. It is strictly forbidden...
Product Details
Model
ENBY-80V/600Ah
Capacity(0.2C5A)
600Ah
Nominal Voltage
80V
Max. Charge Voltage
90V
Discharge Cut-off Voltage
65V(recommended)
Working Voltage Scope
65V~90V
Max. Charge Current
200A
Continuous Discharge current
300A
Max. Discharge current
500A 10Seconds
Weight (Approx.)
450Kgs(without counterweight)
Battery Dimensions
960*770*400mm
Impedance (Max, at 1000Hz)
(Single cell) ≤1mΩ
Cycle Life(80DOD%)
>3000 Times
Self-discharge Rate
≤3%(month)
Charge
Method(CC/CV)
Standard
100A×6.0hrs
Quick
200A×3hrs
Operating Temperature
Charge
0℃~45℃;32oF~113oF
Discharge
-20℃~60℃;-4oF~149oF
Storage
-20℃~45℃;-4oF~113oF
Basic data of BMS
N.0
Item
Spec
Unit
Remark
1
Overcharge protect detection voltage
3.60
V
Adjustable
2
Over-discharge protect detection voltage
2.8
V
Adjustable
3
Over-current protect detect value
600
A
Adjustable
4
Discharge current detection delay time
1 ± 0.5
S
Adjustable
5
Charge continue current
200
A
Adjustable
6
Discharge continue current
300
A
Adjustable
7
Overcharge detection delay time
1 ± 0.5
Sec
Adjustable
8
Over-discharge detection delay time
0.03 ± 0.01
Sec
Adjustable
9
Over current/short circuit release
Restart
10
High-temperature protect detect value
60 ± 3
℃
Adjustable
11
High-temperature release value
55 ± 3
℃
Adjustable
12
Charge Low-temperature protect detect value
0
℃
Adjustable
13
Charge Low-temperature release value
0
℃
Adjustable
14
Discharge Low-temperature protect detect value
-20
℃
Adjustable
15
Discharge Low-temperature release value
-15
℃
Adjustable
16
Balance start_up pressure
20
mV
Adjustable
17
Balance current
100 ± 5
mA
Adjustable
18
Mode of Communication
RS485/CANbus
19
Short circuit protection
Yes
≤800uS
Specification and test curve of battery cells
Specification of battery cells
1
Cell Type
ENBY
2
Material of Case
Aluminum
3
Nominal Voltage
3.2 V
4
Nominal Capacity
100Ah
5
Internal Resistance
<1mW
6
Discharge Cut-off Voltage
2.5V
7
Max Charge Current
100A
8
Max Continuous Discharge Current
1C(100A)
9
Pulse Discharge Current
2C 50%SOC (200A within 10seconds)
10
Max Charge Voltage
3.65V±0.03V
11
Charge method
CC/CV (constant current/constant voltage)
12
Weight
1.97±0.03kg
13
Cycle life
3000 times with 80%DOD
14
Operating Temperature
Charging Temperature: 0~45℃
Discharging Temperature: -20~60℃
15
Storage Temperature
1 month -30~60℃
3 month -20~45℃
1 year -20~45℃
16
Relative Humidity
60±20%
Precautions
The output voltage of the battery product has exceeded the safe voltage range that can be touched by the human body. Please protect it during installation and use. It is strictly forbidden to directly touch the live part of the battery with any part of the body;
Due to the particularity of lithium batteries, under current technical conditions, there are certain risks during use. Please read this manual carefully before installation and use, and operate strictly in accordance with the instructions in the manual, otherwise it may cause damage to the battery, or even Threat to personal safety.
Matters needing attention:
1)Storage and use environment requirements: The storage environment temperature of the battery system must be within the range of -40℃-60℃. The ambient temperature of the battery must be within the range of -20℃-55℃, and the battery cannot be charged when the ambient temperature is lower than 0℃;
2)Keep away from fire sources during storage of the battery system;
3)The battery system should be protected from rain, water, and other corrosive liquids during transportation, storage, and use;
4)The battery system can only be installed on designated forklifts, and cannot be installed on other vehicles or used on other electrical appliances that exceed the battery specifications;
5)The positive and negative poles need to be prevented from short-circuiting during installation;
6)To charge, you must use the matching special charger, or replace the charger under the guidance of our professionals.
7)When the battery system is not in use for a long time (more than 1 hour), the power switch needs to be turned off. After the power is left unused for more than 1 hour, the battery will automatically enter the dormant state, and the system needs to be turned off and wake up again;
8)After the battery enters the dormant state, there is still a small current flowing through the system. Therefore, when the battery is left for a long time (3 months or more), it is necessary to turn off the power and ensure that the battery power is above 40% SOC. Charge and discharge once every three months Maintenance, that is, charge the battery to 50% after it is discharged. Otherwise, the entire battery pack may be over-discharged, and the failure of the entire battery pack caused by this is not covered by the warranty;
Failure to follow the operating instructions or other reasons for improper use is not covered by the warranty.