NWN series Induced Draft Evaporative Closed Circuit Coolers, Closed loop system design, Trouble-free process operation-closed loop protection of process fluids and equipment from external contamination, Widely used in data centres, battery plants, grow room facilities, high-efficiency chiller applications and multiply different types of industrial process.

NWN series Induced Draft Evaporative Closed Circuit Coolers, Closed loop system design, Trouble-free process operation-closed loop protection of process fluids and equipment from external contamination. For example cold weather operation, please turn off the sprinkler system and operate in a dry state during the load reduction. This type counter flow closed cooling tower is widely used in data centres, battery plants, grow room facilities, high-efficiency chiller applications and multiply different types of industrial process.
Equipment can be ordered according to singlecell or multi cells. | Features ► Large internal space & smaller occupied area ► Excellent heat exchange performance & smaller wind resistant ► Non-stop maintenance & simple maintenance work ► Closed circuit design ensures high water quality |  |
Frame structure
Modular structure, use the high quality of zinc magnesium aluminum material (304 or 316 stainless steel for option), which is standardization made by Z700 galvanized anti-corrosion processing.After passivation treatment, cooling tower can withstand water PH value 6.5-9.0 . At the same time, the component design strength can bear the wind pressure of 1440 Pa, Protected the product quality and ensured stable running.
Stainless steel Cooling Coil
& Easy disassembled type inlet grille
▷ Stainless steel Cooling Coil, longer equipment life, higher thermal efficiency, higher corrosion resistance, lighter, recyclable.
Process fluid is circulated through 304 stainless steel coil in closed loop system, reduced water treatment chemicals, reduced water consumption.
▷ Easy disassembled type inlet grille, special 3D stereo 45-degree ventilation channel, greatly improves product and wind load resistance.
Reduce noise and prevent the growth of algea. Anti-corrosion, anti-ultraviolet, maintenance-free.

High efficient fan drive system
& PVC drift eliminator
▷ High efficient fan drive system, Small wind resistance, big air volume, low noise, good performance, high efficiency. Streamline high strength fan stack gurantees airflow uniform through the fan inlet and outlet area, maximum reduce the energy comsuption. Fan motor's protection class: IP55, Insulation class: F class.
▷ NEWIN EVD series drift eliminator , using advanced self-extinguishing PVC materials with high thermal performance. Capture large water droplets caught in the cooling tower air stream,improving high thermal transfer performance.

Optional Accessories
Noise reduction upgrade / Anti-Freeze heater / Vibration isolator / Stainless steel casing and framework / bolts and nuts (304 / 316)
High-temperature upgrade / Dual-speed Motor & VFD motorAnti-Freeze heater
Application
- HVAC system - Pharmaceutical industry - HVAC system
- Chemical industry - Machinery manufacturing - Metal processing
- Plastic products - Industrial refrigeration - Food processing

TECHNICAL SPECIFICATION OF NWN SERIES COOLING TOWER
设计工况
Design Conditions
进水 Entrance temp. t1= 37℃ 湿球 Wet bulb temp. tWB= 28℃ 大气压力 Atmospheric pressure P0= 9.94 x 104 Pa
出水 Leaving temp. t2 = 32℃ 干球 Dry bulb temp. tDB= 31.5℃ 型号 Model | 制冷量 Cooling Capacity (Kw) | 风机 Fan Power (Kw) | 水泵 Pump Power (Kw) | 尺寸 Dimension (mm) | 重量 Weight (kg) |
长度 Length | 宽度 Width | 高度 Height | 净重 Dry | 运行重量Wet |
| NWN-230-Z7-S | 230 | 1.5*2 | 0.75Kw | 2500 | 1100 | 2750 | 2950 | 5000 |
| NWN-290-Z7-S | 290 | 1.5*2 | 0.75Kw | 2500 | 1100 | 2750 | 3150 | 5500 |
| NWN-350-Z7-S | 350 | 2.2*2 | 1.1Kw | 2500 | 1200 | 2750 | 3350 | 6000 |
| NWN-450-Z7-S | 450 | 2.2*3 | 1.5Kw | 4250 | 1450 | 3100 | 4150 | 6800 |
| NWN-600-Z7-S | 600 | 2.2*3 | 1.5Kw | 4250 | 1450 | 3100 | 5550 | 7800 |
| NWN-750-Z7-S | 750 | 5.5*2 | 2.2Kw | 4250 | 1750 | 3520 | 6050 | 8500 |
| NWN-850-Z7-S | 850 | 5.5*2 | 2.2Kw | 4250 | 2250 | 3620 | 7120 | 10500 |
| NWN-1000-Z7-S | 1000 | 5.5*2 | 3.0Kw | 4250 | 2250 | 3620 | 7150 | 9500 |
| NWN-1150-Z7-S | 1150 | 7.5*2 | 4.0Kw | 5750 | 2250 | 3860 | 7720 | 11500 |
| NWN-1300-Z7-S | 1300 | 7.5*2 | 5.5Kw | 5750 | 2250 | 3860 | 8300 | 12700 |
| NWN-1450-Z7-S | 1450 | 11*2 | 5.5Kw | 5750 | 2500 | 4240 | 10680 | 14600 |
| NWN-1750-Z7-S | 1750 | 11*2 | 7.5Kw | 5750 | 3000 | 4340 | 12100 | 16200 |
型号 Model | 管径尺寸 Pipe Size(DN) |
进水 Inlet | 出水 Outlet | 自动补水 Auto Feed | 手动补水 Quick Feed | 满水 Overflow | 排污 Drain |
| NWN-230-Z7-S | 100 | 100 | 25 | 40 | 40 | 40 |
| NWN-290-Z7-S | 100 | 100 | 25 | 40 | 40 | 40 |
| NWN-350-Z7-S | 100 | 100 | 25 | 40 | 40 | 40 |
| NWN-450-Z7-S | 125 | 125 | 25 | 40 | 40 | 40 |
| NWN-600-Z7-S | 125 | 125 | 25 | 40 | 40 | 40 |
| NWN-750-Z7-S | 100*2 | 100*2 | 40 | 40 | 50 | 50 |
| NWN-850-Z7-S | 100*2 | 100*2 | 40 | 40 | 50 | 50 |
| NWN-1000-Z7-S | 100*2 | 100*2 | 40 | 40 | 50 | 50 |
| NWN-1150-Z7-S | 100*2 | 100*2 | 40 | 40 | 50 | 50 |
| NWN-1300-Z7-S | 100*2 | 100*2 | 40 | 40 | 50 | 50 |
| NWN-1450-Z7-S | 125*2 | 125*2 | 40 | 40 | 50 | 50 |
| NWN-1750-Z7-S | 150*2 | 150*2 | 40 | 40 | 50 | 50 |
* 此样本仅包含发行时的数据,请勿直接用于工程施工,具体的资料需要在购买时进一步于销售工程师确认。如需多台联合机组,请咨询厂家提供方案。
NEWIN 保留更改上表参数或尺寸而不另行通知的权利。
This table sample only contanins the data when issued, please do not use for engineering construction. Please further to confirm with sales and engineer
about the detailed data before purchasing. If need muti-cells, please consult the manufacturer to providethe solutions. NEWIN reserves the right to change
the parameters or dimensions of the table without notice.