1. Differential Pressure Transmitter (AP) 2. Measured media: Gas, steam, liquid 3. Measured range(with no shift): 0PA~100PA…3MPa 4. Basic error: ±0.075% 5. Diaphragm contacting with liquid: Stainless Steel 316L, Hast-alloy C
Overview:
| Features | Applications: |
| 1. High reference accuracy up to 0.075%, higher on request. | 1. Gauge, absolute and differential pressure measurement in gases, steam or liquids in all areas of of engineering process and measurement. |
| 2. Long-term drift ≤±0.15%URL for 5 years. |
| 3. Range down ratio 100:1; higher on request. | 2. Level, volume or mass measurement in liquids. |
| 4. Replaceable display unit & electronic module. |
| 5. Universal electronics. | 3. Working with detecting element, measure the flow of gases, steam and liquid flow.( volume and mass flow) |
| 6. Menu-guided operation. |
| 7. Factory default data recovery is supportive |
| 8. HART,PROFIBUS-PA or FF protocol for option. | 4. High pressure up to 40bar. |
Overview:
| Features | Applications: |
| 1. High reference accuracy up to 0.075%, higher on request. | 1. Gauge, absolute and differential pressure measurement in gases, steam or liquids in all areas of of engineering process and measurement. |
| 2. Long-term drift ≤±0.15%URL for 5 years. |
| 3. Range down ratio 100:1; higher on request. | 2. Level, volume or mass measurement in liquids. |
| 4. Replaceable display unit & electronic module. |
| 5. Universal electronics. | 3. Working with detecting element, measure the flow of gases, steam and liquid flow.( volume and mass flow) |
| 6. Menu-guided operation. |
| 7. Factory default data recovery is supportive |
| 8. HART,PROFIBUS-PA or FF protocol for option. | 4. High pressure up to 40bar. |
| Technical Data |
| Applicable media | liquid, gas and steam |
| Pressure range | -100kPa~10MPa |
| Accuracy | 0.075%, higher on request |
| Stability | ±0.15% of URL for 5 years |
| Temperature drift | ±0.03% of URL/10ºC |
| Output signals | 4~20mA, Hart, Profibus-PA for option, FF per request |
| Display | LCD, or pointer optional |
| Housing material | Aluminum14 |
| Mechanical connection | M20×1.5;G1/2;1/2NPT |
| Protection class | IP66/67 |
| Ex-proof | Exia II CT4, other option per request |
| Power Supply | 10.5-55V DC 10.5-30V DC |
| Ambient temperature | -40 to 85ºC,-40 to 80ºCfor LCD header |
| Storage temperature | -45 to 85ºC,-40 to 80ºC for LCD header ; |
| Measurement | with display: 95*126*52 (mm) |
| without display: 95*115*52 (mm) |
| Net Weight | 4kg (without bracket or process connection) |
| Technical Data |
| Applicable media | liquid, gas and steam |
| Pressure range | -100kPa~10MPa |
| Accuracy | 0.075%, higher on request |
| Stability | ±0.15% of URL for 5 years |
| Temperature drift | ±0.03% of URL/10ºC |
| Output signals | 4~20mA, Hart, Profibus-PA for option, FF per request |
| Display | LCD, or pointer optional |
| Housing material | Aluminum14 |
| Mechanical connection | M20×1.5;G1/2;1/2NPT |
| Protection class | IP66/67 |
| Ex-proof | Exia II CT4, other option per request |
| Power Supply | 10.5-55V DC 10.5-30V DC |
| Ambient temperature | -40 to 85ºC,-40 to 80ºCfor LCD header |
| Storage temperature | -45 to 85ºC,-40 to 80ºC for LCD header ; |
| Measurement | with display: 95*126*52 (mm) |
| without display: 95*115*52 (mm) |
| Net Weight | 4kg (without bracket or process connection) |
Differential Pressure Transmitter dimensions:

Differential Pressure Transmitter dimensions:

Differential Pressure Transmitter order guide:
| NS-3051AP | Intelligent Differential Pressure Transmitter |
|
|
| Code | Output |
|
| H | 4mA~20mA DC with HART |
|
| N | 4mA~20mA DC analog output |
|
|
| Code | Pressure range |
|
| A | 0PA…100PA~1kPa(0mm…10mm~100 mm H2O)/(0mbar…1mbar ~10mbar) |
|
| B | 0PA…200PA~6kPa(0mm…20mm~600 mm H2O)/(0mbar…2mbar ~60mbar) |
|
| C | 0PA…400PA~40kPa(0mm…40mm~4000 mm H2O)/(0mbar…20mbar ~400mbar) |
|
| D | 0kPa…2.5kPa~250kPa(0m…0.25m~25 m H2O)/(0mbar…25mbar ~2500mbar) |
|
| F | 0kPa…30kPa~3MPa(0m…3m~300 m H2O)/ (0bar…0.3bar~30bar) |
|
|
| Code | Diaphragm material Filling |
|
|
| A | Stainless steel316L silicone oil |
|
| C | Hastelloy C silicone oil |
|
|
| Code | Rated working pressure |
|
| 0 | 0.2MPa (only for range A) |
|
| 7 | 7MPa (only for range A) |
|
| 1 | 16MPa |
|
| 2 | 25MPa |
|
| 3 | 40MPa |
|
|
| Code | Process connection |
| N | 1/4 NPT and 7/16 UNF thread hole without release valve |
| B | 1/4 NPT and 7/16 UNF thread hole, release valve mounting in the end-face of flange back |
| U | 1/4 NPT and 7/16 UNF thread hole, release valve mounting in upper flange side |
| D | 1/4 NPT and 7/16 UNF thread hole, release valve mounting in lower flange side |
|
| Code | Sealing materials contacting with liquid |
| N | NBR |
| F | FKM |
| P | PTFE |
|
|
| Code | Additional function |
|
| N | None |
|
| F | Square root output |
|
| O | No oil processing(For oxygen measurement: Fluorocarbon oil filling, viton sealing ring, <6MPa, <60ºC) |
|
|
| Code | Mounting bracket |
|
| N | None |
|
| 1 | Stainless steel |
|
| 2 | Galvanized Carbon Steel |
|
|
| Code | Process connection parts |
|
| N | None |
|
| 1 | 1/2 NPT Female with stainless steel oval flange |
|
| 2 | M20X1.5 male with stainless steel T joint |
|
| 3 | 1/2-14NPT guiding pressure transition joint and rear welding guiding Pressure tube (SS) |
|
|
|
| Code | Display |
|
| 1 | LCD |
|
| 2 | LCD with back-light |
|
|
|
|
|
|
|
|
| Code | Others |
|
| N | None |
|
| A | Intrinsic safe |
|
| D | Exd |
|
| E | Exd version with Explosion-proof cable joint |
|
| S | Stainless steel 316 plate |
|
|
|
|
|
| NS-3051-AP H C A 1 B N F 1 1 1 N The whole spec |
|
Differential Pressure Transmitter order guide:
| NS-3051AP | Intelligent Differential Pressure Transmitter |
|
|
| Code | Output |
|
| H | 4mA~20mA DC with HART |
|
| N | 4mA~20mA DC analog output |
|
|
| Code | Pressure range |
|
| A | 0PA…100PA~1kPa(0mm…10mm~100 mm H2O)/(0mbar…1mbar ~10mbar) |
|
| B | 0PA…200PA~6kPa(0mm…20mm~600 mm H2O)/(0mbar…2mbar ~60mbar) |
|
| C | 0PA…400PA~40kPa(0mm…40mm~4000 mm H2O)/(0mbar…20mbar ~400mbar) |
|
| D | 0kPa…2.5kPa~250kPa(0m…0.25m~25 m H2O)/(0mbar…25mbar ~2500mbar) |
|
| F | 0kPa…30kPa~3MPa(0m…3m~300 m H2O)/ (0bar…0.3bar~30bar) |
|
|
| Code | Diaphragm material Filling |
|
|
| A | Stainless steel316L silicone oil |
|
| C | Hastelloy C silicone oil |
|
|
| Code | Rated working pressure |
|
| 0 | 0.2MPa (only for range A) |
|
| 7 | 7MPa (only for range A) |
|
| 1 | 16MPa |
|
| 2 | 25MPa |
|
| 3 | 40MPa |
|
|
| Code | Process connection |
| N | 1/4 NPT and 7/16 UNF thread hole without release valve |
| B | 1/4 NPT and 7/16 UNF thread hole, release valve mounting in the end-face of flange back |
| U | 1/4 NPT and 7/16 UNF thread hole, release valve mounting in upper flange side |
| D | 1/4 NPT and 7/16 UNF thread hole, release valve mounting in lower flange side |
|
| Code | Sealing materials contacting with liquid |
| N | NBR |
| F | FKM |
| P | PTFE |
|
|
| Code | Additional function |
|
| N | None |
|
| F | Square root output |
|
| O | No oil processing(For oxygen measurement: Fluorocarbon oil filling, viton sealing ring, <6MPa, <60ºC) |
|
|
| Code | Mounting bracket |
|
| N | None |
|
| 1 | Stainless steel |
|
| 2 | Galvanized Carbon Steel |
|
|
| Code | Process connection parts |
|
| N | None |
|
| 1 | 1/2 NPT Female with stainless steel oval flange |
|
| 2 | M20X1.5 male with stainless steel T joint |
|
| 3 | 1/2-14NPT guiding pressure transition joint and rear welding guiding Pressure tube (SS) |
|
|
|
| Code | Display |
|
| 1 | LCD |
|
| 2 | LCD with back-light |
|
|
|
|
|
|
|
|
| Code | Others |
|
| N | None |
|
| A | Intrinsic safe |
|
| D | Exd |
|
| E | Exd version with Explosion-proof cable joint |
|
| S | Stainless steel 316 plate |
|
|
|
|
|
| NS-3051-AP H C A 1 B N F 1 1 1 N The whole spec |
|