Product description
·Standard and main indicators for the implementation of the steel cord conveyor belt:varietiesStandards and key in
Product specifications
| ·Standard and main indicators for the implementation of the steel cord conveyor belt: | |
| varieties | Standards and key indicators |
| Common type steel wire rope core conveyer belt | GB/T9770-2001 |
| Flame retardant type steel wire rope core conveyer belt | MT668-1997 |
| General flame retardant type steel wire rope core conveyer belt | MT668-1997 |
| Heat resistant type steel wire rope core conveyer belt | HG2297-92 |
| Wear resistant steel wire rope core conveyer belt | Shao Boer wear≤90mm 3 |
| Acid, alkali, oil type steel wire rope core conveyor belt | HG4-846 |
| Cold resistant steel wire rope core conveyer belt | Brittle temperature-40℃ |
·5、Main technical parameters of steel cord conveyor belt (Table 2, table 1, table 3) ·Table 1: |
| Project | St630 | St800 | St1000 | St1250 | St1600 | St2000 | St2500 | St3150 | St3500 | St4000 | St4500 | St5000 | St5400 |
| Longitudinal tensile strength N/mm | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 | 3500 | 4000 | 4500 | 5000 | 5400 |
| Maximum nominal diameter of wire rope mm | 3.0 | 3.5 | 4.0 | 4.5 | 5.0 | 6.0 | 7.2 | 8.1 | 8.6 | 8.9 | 9.7 | 10.9 | 11.3 |
| Wire rope spacing mm | 10±1.5 | 10±1.5 | 12±1.5 | 12±1.5 | 12±1.5 | 12±1.5 | 15±1.5 | 15±1.5 | 15±1.5 | 15±1.5 | 16±1.5 | 17±1.5 | 17±1.5 |
| Thickness of upper covering layer mm | 5 | 5 | 6 | 6 | 6 | 8 | 8 | 8 | 8 | 8 | 8 | 8.5 | 9 |
| Lower covering thickness mm | 5 | 5 | 6 | 6 | 6 | 6 | 6 | 8 | 8 | 8 | 8 | 8.5 | 9 |
| Width specification mm | Number of steel wire rope |
| St630 | St800 | St1000 | St1250 | St1600 | St2000 | St2500 | St3150 | St3500 | St4000 | St4500 | St5000 | St5400 |
| 800 | 75 | 75 | 63 | 63 | 63 | 63 | 50 | 50 | 50 | | | | |
| 1000 | 95 | 95 | 79 | 79 | 79 | 79 | 64 | 64 | 64 | 64 | 59 | 55 | 55 |
| 1200 | 113 | 113 | 94 | 94 | 94 | 94 | 76 | 76 | 77 | 77 | 71 | 66 | 66 |
| 1400 | 133 | 133 | 111 | 111 | 111 | 111 | 89 | 89 | 90 | 90 | 84 | 78 | 78 |
| 1600 | 151 | 151 | 126 | 126 | 126 | 126 | 101 | 101 | 104 | 104 | 96 | 90 | 90 |
| 1800 | | 171 | 143 | 143 | 143 | 143 | 114 | 114 | 117 | 117 | 109 | 102 | 102 |
| 2000 | | | 159 | 159 | 159 | 159 | 128 | 128 | 130 | 130 | 121 | 113 | 113 |
| 2200 | | | | | | 176 | 141 | 141 | 144 | 144 | 134 | 125 | 125 |
| 2400 | | | | | | 193 | 155 | 155 | 157 | 157 | 146 | 137 | 137 |
| 2600 | | | | | | 209 | 168 | 168 | 170 | 170 | 159 | 149 | 149 |
| 2800 | | | | | | | | | 194 | 194 | 171 | 161 | 161 |
| Level code | tensile strength,MPa ≥ | Elongation at break,% ≥ | Wear quantity,mm 3 ≤ |
| D | 18 | 400 | 90 |
| H | 25 | 450 | 120 |
| L | 20 | 400 | 150 |
| P | 14 | 350 | 200 |
注:D - strong wear working conditions; H - strong working conditions; L - General working conditions; P—Resistant to oil, acid and alkali resistant, cold resistant and generally difficult to burn conveyor belt |
·6、Calculation method of measuring unit for steel cord conveyor belt(Measure unit:m 2 ) computing method:Total number of squares=Bandwidth M×With thick mm1.5mm×Take long(m) |