Product description
Standard and main index for the implementation of the steel cord conveyor belt:Variety
Product specifications

Standard and main index for the implementation of the steel cord conveyor belt:
Variety standard and main index
Ordinary type steel wire rope core conveyor belt GB/T9770-2001
Flame retardant type steel wire rope core conveyor belt MT668-1997
General flame retardant steel wire rope core conveyor belt MT668-1997
Heat resistant steel wire rope core conveyor belt HG2297-92
Wear resistant steel cord conveyor belt wear burr Shao is less than 90mm 3
Acid, alkali, oil type steel wire rope core conveyor belt HG4-846
Cold proof steel wire rope core conveyor belt brittle temperature -40
5, the main technical parameters of the steel cord conveyor belt (Table 2, table 1, table 3)
Table 1:
| Project | St630 | St800 | St1000 | St1250 | St1600 | St2000 | St2500 | St3150 | St3500 | St4000 | St4500 | St5000 | St5400 |
| Longitudinal tensile strength N/mm | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 | 3500 | 4000 | 4500 | 5000 | 5400 |
| Maximum nominal diameter of wire rope mm | 3.0 | 3.5 | 4.0 | 4.5 | 5.0 | 6.0 | 7.2 | 8.1 | 8.6 | 8.9 | 9.7 | 10.9 | 11.3 |
| Wire rope spacing mm | 10±1.5 | 10±1.5 | 12±1.5 | 12±1.5 | 12±1.5 | 12±1.5 | 15±1.5 | 15±1.5 | 15±1.5 | 15±1.5 | 16±1.5 | 17±1.5 | 17±1.5 |
| Thickness of upper covering layer mm | 5 | 5 | 6 | 6 | 6 | 8 | 8 | 8 | 8 | 8 | 8 | 8.5 | 9 |
| Lower covering thickness mm | 5 | 5 | 6 | 6 | 6 | 6 | 6 | 8 | 8 | 8 | 8 | 8.5 | 9 |
Table two:| Width specification mm | Number of steel wire rope |
| St630 | St800 | St1000 | St1250 | St1600 | St2000 | St2500 | St3150 | St3500 | St4000 | St4500 | St5000 | St5400 |
| 800 | 75 | 75 | 63 | 63 | 63 | 63 | 50 | 50 | 50 | | | | |
| 1000 | 95 | 95 | 79 | 79 | 79 | 79 | 64 | 64 | 64 | 64 | 59 | 55 | 55 |
| 1200 | 113 | 113 | 94 | 94 | 94 | 94 | 76 | 76 | 77 | 77 | 71 | 66 | 66 |
| 1400 | 133 | 133 | 111 | 111 | 111 | 111 | 89 | 89 | 90 | 90 | 84 | 78 | 78 |
| 1600 | 151 | 151 | 126 | 126 | 126 | 126 | 101 | 101 | 104 | 104 | 96 | 90 | 90 |
| 1800 | | 171 | 143 | 143 | 143 | 143 | 114 | 114 | 117 | 117 | 109 | 102 | 102 |
| 2000 | | | 159 | 159 | 159 | 159 | 128 | 128 | 130 | 130 | 121 | 113 | 113 |
| 2200 | | | | | | 176 | 141 | 141 | 144 | 144 | 134 | 125 | 125 |
| 2400 | | | | | | 193 | 155 | 155 | 157 | 157 | 146 | 137 | 137 |
| 2600 | | | | | | 209 | 168 | 168 | 170 | 170 | 159 | 149 | 149 |
| 2800 | | | | | | | | | 194 | 194 | 171 | 161 | 161 |
Table three:| Level code | The tensile strength is more than MPa, | The elongation at break,% > | The wear volume is less than or equal to 3 mm. |
| D | 18 | 400 | 90 |
| H | 25 | 450 | 120 |
| L | 20 | 400 | 150 |
| P | 14 | 350 | 200 |
Note: D - strong wear working conditions; H - strong work under the conditions of crack; L - General working conditions;
P oil resistant, acid and alkali resistant, cold resistant and generally difficult to burn conveyor belt
6, the calculation method of the measuring unit for the steel cord conveyor belt (M 2)
Calculation method: the total number of square = bandwidth m x with a thick mm1.5mm x Length (m)