SUP-110T Economic 3-digit Single-loop Digital Display Controller

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
City, Province
Overview
Economic 3-digit Single-loop Digital Display Controller is in modular structure, easily operable, cost-effective, applicable in light industry machinery, ovens, laboratory equipment, heating/cooling and other objects in the temperature range of 0~999 C.
Product Details
  • Specification
 Product Digital Single-loop digital display controller
 ModelSUP-110T
 DisplayDual-screen LED display
 DimensionC. 96*96*110mm
D. 96*48*110mm
E. 48*96*110mm
F. 72*72*110mm
H. 48*48*110mm
Measurement accuracy

±0.3%FS

Analog outputAnalog output----4-20mA、1-5V(RL≤500Ω)、1-5V(RL≥250kΩ)
Alarm OutputWith upper and lower limit alarm function, with alarm return difference setting;Relay contact capacity:
AC125V/0.5A(small)DC24V/0.5A(small)(Resistance C load)
AC220V/2A(big)DC24V/2A(big)(Resistive load)
Note: When the load exceeds the relay contact capacity, please do not directly carry the load
Power supplyAC/DC100~240V (Frequency50/60Hz) Power consumption≤5W
DC 12~36V  Power consumption≤3W
Use environment

Operating temperature(0~50℃)

Relative humidity:(5~85%)RH

 

  • Introduction

single-loop-digital-meter

digital meter

Economic 3-digit Single-loop Digital Display Controller is in modular structure, easily operable, cost-effective, applicable in light industry machinery, ovens, laboratory equipment, heating/cooling and other objects in the temperature range of 0~999 °C. The instrument displays with dual row 3-digit numeric tube, with a variety of RTD/TC input signal types optional with an accuracy of 0.3%; 5 sizes optional, supporting 2 alarm functions, with transmission output. Optical isolation for input terminal, output terminal, a power supply terminal, 100-240V AC/DC or 12-36V DC switching power supply, standard snap-on installation, ambient temperature at 0-50 °C, and the relative humidity of 5-85% RH (no condensation).

 Terminal Assignments and Dimensions:

    (1) PV display window (measured value)
    (2) SV display window
    In measurement state, the display is defined by dis in the level-1 parameters; in parameters setting state, it displays the set value.
    (3) The first alarm (AL1) and the second alarm (AL2) indicators, running lights (OUT), A/M indicators without effect
    (4) Confirm key
    (5) Shift key
    (6) Down key
    (7) Up key

digital controller

Input signal type list:

Graduation Number PnSignal typeMeasure rangeGraduation Number PnSignal typeMeasure range
0TC B100~999℃5TC J0~999℃
1TC S0~999℃6TC R0~999℃
2TC K0~999℃7TC N0~999℃
3TC E0~999℃11RTD Cu50-50~150℃
4TC T0~400℃14RTD Pt100-199~650℃