Welcome Customer !

Membership

Supmea Automation Co.,Ltd
Free Member ·1YRS
,
Manufacturer

Main Products: Flowmeter|Liquid Level Instrument|Pressure Transmitter|Temperature Sensor

Xwboo>Products
Product Categories

Supmea Automation Co.,LtdFree·1YRS

  • E-mail

    info@supmea.com

  • Phone

  • Address

Contact Now

SUP-MPP1000 Multi-parameter analyzer

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
City, Province
Overview
The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.
Product Details

Item

Index

Value

System

working power

(220±22)VAC,(50±1)Hz

Power

30W

Cabinet size

800mm*506mm*180mm (standard version)

Weight

about 15Kg

Storage temperature

4℃~+50℃

Working temperature

4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module)

Working humidity

≤95%RH (no condensation)

Inlet flow

500~1000 mL/min

Inlet pressure

< 3kg/cm³

Communication interface

RS485 Modbus RTU communication protocol + wireless interface

Turbidity

Range

0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU

Resolution

0-1NTU / 0-20NTU / 0-100NTU:0.001NTU

0-4000NTU:0.01NTU

Lower detection limit

0.02NTU;0.1NTU(0-4000NTU)

Zero drift

≤1.5%

Indication stability

≤1.5%

Accuracy

2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU)

Repeatability

≤3%

Response time

T90≤120s

Recommended maintenance period

3-12 months (depending on the water quality on site)

Residual chlorine/chlorine dioxide

Range

0-5mg/L / 0-20mg/L

Resolution

0.01mg/L

Lower detection limit

0.05mg/L

Accuracy

±0.05mg/L or ±5% (DPD comparison error ±10%)

Response time

≤120 seconds

Recommended maintenance period

1-3 months or weekly calibration, 3-6 months to replace consumables

PH /ORP(optional)

Range

0-14pH, ±2000mV(ORP)

Resolution

0.01pH, ±1mV(ORP)

Accuracy

±0.1pH, ±20mV(ORP)or ±2%

Repeatability

±0.1pH, ±10mV(ORP)

Response time

≤60 seconds

Recommended maintenance period

1-3 months

Temperature

Range

0℃ - 50℃

Resolution

0.1℃

Accuracy

±0.5℃

Repeatability

≤0.5℃

Response time

≤25 seconds

Recommended maintenance period

12 months

Conductivity (Optional)

Range

0-2000uS/cm 

Accuracy

±1.5%FS

Repeatability

≤0.5%FS

Response time

≤30 seconds

Recommended maintenance period

3-6 months

Dissolved oxygen (Optional)

Range

0-20mg/L

Accuracy

±0.3mg/L

Repeatability

≤±1.5%

Response time

≤30 seconds

Recommended maintenance period

1-3 months

Expansion port

Port type

RS485、4-20mA

 

  • Introduction

The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.

Multi-parameter analyzer