Conductors: Class I, tin coated, soft drawn, annealed, flexible rope-lay, stranded copper construction per ASTM B-33 and B-172
STRAND SHIELD: Extruded semi-conductive layer
CONDUCTOR INSULATION: Lead free, flame resistant, Ethylene Propylene Rubber (EPR) per ICEA S-75-381/NEMA WC-58
INSULATION SHIELDS: Extruded semi-conductive layer under a tinned, annealed, copper braid (60% minimum phase coverage), duplexed with a nylon denier textile phase color ID tracer (40% max phase cover).
Color Code: Black, White, Red
Ground WIRES: Class I, uninsulated tin coated, soft drawn, annealed, rope bunched, flexible lay strand construction copper per ASTM B-33 and B-172.
GROUND CHECK: #16 AWG tinned, annealed copper, rope bunched, flexible lay, extensible strand
construction, with 45 mils of polypropylene (PPE) per ASTM B-33, and B-172, ICEA S-75-381/NEMA WC-58, CAN/CSA-C22.2 No. 96 Portable Power Cable Type SHD-GC and SHD-BGC.
CABLING: Three insulated and shielded conductors assembled in a helical configuration with three uninsulated ground wires laid in the interstices to create a balanced assembly. A #16 AWG extensible yellow insulated ground check placed in the center interstice of the cable with a woven nylon polyester binder served over the
entire cabled assembly for added core stability per ICEA S-75-381/NEMA WC-58, CAN/CSA-C22.2 No 96 Portable Power Cable Type SHD-GC and SHD-BGC.
Inner Jacket: Extruded pure integral filled black MSHA approved flame resistant thermosetting Chlorinated Polyethylene (CPE) designed to lock cabled assembly in place to combat core movement and de-cabling in highly torsional applications.
JACKET REINFORCEMENT: A woven nylon polyester binder shall be served between the inner and outer jacket layers providing increased cable integrity. Also available with taped core.
OUTER Jacket: Mold cured, extra heavy-duty, thermosetting Chlorinated Polyethylene (CPE).
JACKET PRINT: Permanent marking, MFG, Brand, AWG size, type, voltage, operation temp range.