The Digital Liquid Turbine Flow Meter is intelligent type flow meter for non-corrosive liquid measuring.The Intelligent transmitter will get and enlarge the signal from the sensor and display on the screen.User can see the current flow rate and accumulate flow amount.The digital liquid turbine flow meter can also output the signal by 4-20mA and pulse to data loggers. Now the digital liquid turbine flow meter is widely used for water, fuel oil, food liquid,solvent measuring.The response of performance are all very g......
Product Details
Digital Liquid Turbine Flow Meter
The Digital Liquid Turbine Flow Meter is intelligent type flow meter for non-corrosive liquid measuring.The Intelligent transmitter will get and enlarge the signal from the sensor and display on the screen.User can see the current flow rate and accumulate flow amount.The digital liquid turbine flow meter can also output the signal by 4-20mA and pulse to data loggers. Now the digital liquid turbine flow meter is widely used for water, fuel oil, food liquid,solvent measuring.
Medium
Water,Oil,Diesel,Alcohol,Enthanol,Milk,Beer
Accuracy
0.50%
Flange standard
GB/T 9119-2010, DIN, ANSI, JIS
Output
Pulse, 4-20mA analog output, RS485 (Modbus-RTU protocol), HART
Diameter and installation
Flange connection DN15-DN200
Screw connection: DN4-DN50
Tri-Clamp connection:DN10-DN80
Wafer flange connection: DN4-DN200
Rated Pressure
1.6MPa, 2.5MPa,6.4MPa MAX 42MPa
Medium temperature
Default type T1: -20℃~+80℃ (Standard)
High temp. type T2: -20℃~+120℃ (OEM)
High temp. type T3: -20℃~+150℃(OEM)
Operation condition
Operating temperature: -20℃~+60℃
Related humidity: 5%~90%
Atmospheric pressure: 86kPa~106kPa
Ingress protection
IP65
Explosion proof
ExdIIBT6 (explosion proof type)
The specific selection steps of liquid turbine Flowmeter are as follows:
1. Identification of available measurements, which must be applicable Turbine Flowmeter The media.
2, 316 stainless steel material used in Flowmeter body selection must also be explosion-proof if the explosion-proof area is in the case of anticorrosion.
3. Select the type. According to the selection of fluid physical properties, gas and liquid turbine Flowmeter are selected respectively, which can not be used. When the viscosity of liquid exceeds 5mPa. S, the high viscosity type should be selected. Acid corrosive fluid is acid resistant.
4, bearings generally have three specifications of tungsten carbide polytetrafluoroethylene carbon graphite: the accuracy of tungsten carbide as the standard part of industrial control; polytetrafluoroethylene carbon graphite anticorrosion is generally preferred in chemical places. The square of the life velocity of the bearing is positive and negative, so the velocity of the velocity is better at the speed of 1 ≤ 3.
5, choose according to the environmental conditions, according to the ambient temperature and humidity to select the appropriate instrument, if there is explosive flammability atmosphere around should choose explosion-proof type sensor.
6, according to the pipe connection mode selection, the sensor has horizontal and vertical installation methods. Horizontal installation with pipe connection mode has flange connection, thread connection and clamping connection. Flange connection is selected for medium caliber, thread connection is used for small diameter and high pressure pipeline, and clamping connection is only suitable for low pressure small and medium pipe diameter. Vertical installation has only threaded connections. Large caliber uses plug-in turbine Flowmeter.