The Durable Coriolis Fuel Mass Flow Meter for Marine Oil is a good choice for fuel measuring, will precisely show the fuel consumption to tell the rest amount of the fuel of devices,such as vessel, truck etc.The Durable Coriolis Fuel Mass Flow Meter is normally used for marine oil measuring,for the marine heavy oil, the final user can choose to configure the heating jacket for maintain the fluency of the marine oil.The durable Coriolis Mass Flow Meter is made by all stainless steel which is very durable and suitabl......
Product Details
Coriolis Fuel Mass Flow Meter
The Durable Coriolis Fuel Mass Flow Meter for Marine Oil is a good choice for fuel measuring, will precisely show the fuel consumption to tell the rest amount of the fuel of devices,such as vessel, truck etc.The Durable Coriolis Fuel Mass Flow Meter is normally used for marine oil measuring,for the marine heavy oil, the final user can choose to configure the heating jacket for maintain the fluency of the marine oil.The durable Coriolis Mass Flow Meter is made by all stainless steel which is very durable and suitable for vessel using.
Essential safety Voltage: AC(220±10%)V,(50±5%)Hz;Composite Voltage: DC (24±10%) V
Coriolis Mass Flow Meter is a new type of measuring instrument, which is widely used in the transfer and measurement of fluid. In the use process, due to improper use, the measurement accuracy of the flow meter is reduced, and the service life of the flow meter is greatly shortened.
The installation of Coriolis Mass Flow Meter sensor is very important to the flow measurement and cannot be ignored. The accuracy of the Coriolis Mass Flow Meter is affected by the presence of a non-standard installation or installation of the non-standard in the daily work. Check the operation instructions in detail before installation, and install properly according to the actual process conditions.
Installation of the Coriolis Mass Flow Meter
1. The installation position shall avoid electromagnetic interference. The Coriolis Mass Flow Meter is driven by an electromagnetic coil, and the detection signal is also emitted by the detection coil, and the interference of the electromagnetic field should be avoided to obtain the correct induction signal.
2. The flanges of both sides shall be parallel to the process pipeline. The centerline of the upstream and downstream lines of the mounting sensor shall be on a horizontal line and the flange plane shall be parallel.
3. Install the stop valve and bypass. The stop valve and bypass are installed on the upper and lower pipelines of the sensor so as to be convenient to zero, daily maintenance and ensure that the sensor can also be in full tube state when not working. The flow control is performed using the control valve downstream of the Coriolis Mass Flow Meter.
4. Note the installation direction of the sensor. In order to ensure that the measured medium can be completely filled with the sensor, for the liquid to be non-gas-collecting, for the gas to be non-liquid, for viscous, dirty, high-condensation point, the medium is easy to drain and so on, so the conveying medium is different, and the sensor mounting direction is different.
5. Notes for new pipeline. For the newly-built pipeline, the Coriolis Mass Flow Meter shall be installed after completion of the pipeline preset and pipeline purging, so as to avoid the accidental damage caused by the pipeline construction to the sensor and to avoid the ingress of debris into the sensor.
6. Precautions for electrical connection. The cables of the power supply, the sensor and the transmitter and the output shall be laid separately to prevent mutual interference, and the signal output shall be a twisted control cable with shielding.