The Economic Liquid Turbine Flow Sensor is normally used in quantitative control system,the product remove the display part and only left the signal transmitter for 4-20mA and pulse signal.The Economic Liquid Turbine Flow Sensor can be customized by different connections,like the flange, wafer, thread and tri-clamp. The Economic Liquid Turbine Flow Sensor works well at the field of food, medical, chemical , fuel and other fields.it has become a more and more economic and efficient choice for quantitative control sy......
Product Details
Liquid Turbine Flow Sensor
The Economic Liquid Turbine Flow Sensor is normally used in quantitative control system,the product remove the display part and only left the signal transmitter for 4-20mA and pulse signal.The Economic Liquid Turbine Flow Sensor can be customized by different connections,like the flange, wafer, thread and tri-clamp. The Economic Liquid Turbine Flow Sensor works well at the field of food, medical, chemical , fuel and other fields.it has become a more and more economic and efficient choice for quantitative control system.
Medium
Water,Oil,Diesel,Alcohol,Enthanol,Milk,Beer
Accuracy
0.50%
Flange standard
GB/T 9119-2010, DIN, ANSI, JIS
Output
Pulse, 4-20mA analog output, RS485 (Modbus-RTU protocol), HART
Diameter and installation
Flange connection DN15-DN200
Screw connection: DN4-DN50
Tri-Clamp connection:DN10-DN80
Wafer flange connection: DN4-DN200
Rated Pressure
1.6MPa, 2.5MPa,6.4MPa MAX 42MPa
Medium temperature
Default type T1: -20℃~+80℃ (Standard)
High temp. type T2: -20℃~+120℃ (OEM)
High temp. type T3: -20℃~+150℃(OEM)
Operation condition
Operating temperature: -20℃~+60℃
Related humidity: 5%~90%
Atmospheric pressure: 86kPa~106kPa
Ingress protection
IP65
Explosion proof
ExdIIBT6 (explosion proof type)
Liquid Turbine Flow Sensor Product Feature
The reproducibility is good, and the short-term repeatability can reach 0.05% ≤ 0.2%. Because of its good repeatability, such as frequent calibration or on-line calibration, it can obtain very high accuracy and is the preferred Flowmeter in trade settlement.
High precision, generally up to ±1% R, ±0.5% R, high precision type can reach ±0.2% R.