Kiln is an important ceramic production equipment, is the main part of investment in ceramic production enterprises. In the process of ceramic production, once the kiln is put into use, it will not stop operation unless it is shut down or in an emergency.The gas flow rate of kiln is affected by furnace temperature. Generally speaking, the flow fluctuation range is small, so the gas turbine flowmeter is very suitable for selection. Gas turbine flowmeter has a long history of developmentand abundant experimental data......
Product Details
Kiln Fuel Gas Turbine Flow Meter
The gas flow rate of kiln is affected by furnace temperature. Generally speaking, the flow fluctuation range is small, so the gas turbine flowmeter is very suitable for selection. Gas turbine flowmeter has a long history of development and abundant experimental data,Due to its mature technology, high accuracy, good repeatability and small pressure loss, it was selected as the legal measuring instrument in developed countries and widely used in business measurement occasions.
Main Application
Natural Gas,LPG,Compressed Air,Nitrogen
Nominal Diameter
DN25-DN300
Span
2.5-6500m³/h
Rated Pressure
1.6MPa~4.0MPa
Accuracy Level
±1.5%R 1.0% Selectable
Repeatablility
±0.1%
Range Ration
1:10,
Material
Body/Rotor Support:SS304(SS316L optional)
Impeller:Double Phase Steel
Shaft:Stainless Steel
Bearing:Stainless Steel Ball Bearing
Process Connection
Flange/Thread NPT/Wafer
Working Condition
Medium Temperature:-20℃~+80℃
(Max Customize to150℃)
Ambient Temperature:-20℃~+60℃
Rated Humidity:5%~90%
Ambient Pressure:86KPa~106KPa
Power
24VDC
3V 10AH lithium battery.
Consumption
24VDC power:<1W
Battery:≤1W,lifetime>3yrs
Signal Output
Pulse,4-20mA,Switch Signal.
DIgital Communication
RS485,MODBUS,HART,PROFIBUS-DP
Signal wire joint
Hausman joint/Inner screw M20*1.5 or customized
Explosion Proof Grade
ExdIIBT6/ExiaIICT4
Degree of Protection
IP65 or Higher
The technical measures to prevent the gas turbine wheel from jamming
Pipeline configuration
1) The installed straight pipe section is in accordance with the manufacturer's requirements, and bypass pipe is recommended for gas turbine flowmeter
2) During the pressure regulating process, the pressure shall be adjusted slowly to protect the flowmeter;
3) When the flow is overloaded, it is recommended to use the flowmeter a restrictor (restriction orifice or restriction nozzle) is installed downstream.
2. filter
In field application, it is recommended to install filter between flowmeter and upstream valve.
3.On / off valve operation
Open / close the valve in strict accordance with the manufacturer's requirements. When opening the valve, slowly open the upstream valve first, and then slowly open the downstream valve after the pressure at both ends of the flowmeter is balanced; when closing the valve, slowly close the downstream valve first, and then slowly close the upstream valve.
4 add lubricating oil
After installation and before putting into use, add enough lubricating oil according to the instructions (oil pump indicator), and shorten the oil filling cycle when the gas quality is dirty.