For some special conditions of small caliber and small flow, low flow gas turbine flowmeter is very suitable. The low flow gas turbine flowmeter has an initial flow of 1m3 / h, and the range ratio can reach 1:20, 1:30, and accuracy level It can reach class 1.0, and its diameter can be DN20 or even smaller. The installation method of low-flow gas turbine flowmeters can be selected from flange, screw, and clamp installation methods. The low flow gas turbine flowmeter is particularly suitable for the measurement of ga......
Product Details
Low Flow Gas Turbine Flow Meter
For some special conditions of small caliber and small flow, low flow gas turbine flowmeter is very suitable. The low flow gas turbine flowmeter has an initial flow of 1m3 / h, and the range ratio can reach 1:20, 1:30, and accuracy level It can reach class 1.0, and its diameter can be DN20 or even smaller. The installation method of low-flow gas turbine flowmeters can be selected from flange, screw, and clamp installation methods. The low flow gas turbine flowmeter is particularly suitable for the measurement of gas flow in various low flow situations.
Low flow gas turbine flow meters can measure media: natural gas, gas, nitrogen, air, propane, ethane, city gas, acetylene and other gases.
Main Application
Natural Gas,LPG,Compressed Air,Nitrogen
Nominal Diameter
DN25-DN300
Span
2.5-6500m³/h
Rated Pressure
1.6MPa~4.0MPa
Accuracy Level
±1.5%R 1.0% Selectable
Repeatablility
±0.1%
Range Ration
1:10,
Material
Body/Rotor Support:SS304(SS316L optional)
Impeller:Double Phase Steel
Shaft:Stainless Steel
Bearing:Stainless Steel Ball Bearing
Process Connection
Flange/Thread NPT/Wafer
Working Condition
Medium Temperature:-20℃~+80℃
(Max Customize to150℃)
Ambient Temperature:-20℃~+60℃
Rated Humidity:5%~90%
Ambient Pressure:86KPa~106KPa
Power
24VDC
3V 10AH lithium battery.
Consumption
24VDC power:<1W
Battery:≤1W,lifetime>3yrs
Signal Output
Pulse,4-20mA,Switch Signal.
DIgital Communication
RS485,MODBUS,HART,PROFIBUS-DP
Signal wire joint
Hausman joint/Inner screw M20*1.5 or customized
Explosion Proof Grade
ExdIIBT6/ExiaIICT4
Degree of Protection
IP65 or Higher
Types of gas turbine flow meter
1. Basic gas turbine flowmeter
The sensor itself has no on-site display function, and only transmits the flow signal remotely. The flow signal can be divided into pulse signal or current signal (4-20mA); the instrument is inexpensive, highly integrated, and small in size, and is particularly suitable for use with computer control systems such as secondary display instruments, PLC, and DCS.
2.Intelligent integrated gas turbine flowmeter
Integrated gas turbine flow meter, a new type of intelligent instrument integrating the turbine flow sensor and display integration developed by advanced ultra-low-power single-chip microcomputer technology. It adopts dual-row liquid crystal field display with compact mechanism, intuitive and clear reading, and reliable. It has obvious advantages such as high performance, no interference from external power, anti-lightning, and low cost. The meter has three-point correction of the meter coefficient, intelligently compensates for the non-linearity of the meter coefficient, and can be corrected on site. The high-definition liquid crystal display simultaneously displays the instantaneous flow rate (4 significant digits) and the accumulated flow rate (8 significant digits, with a clear function). All valid data will not be lost for 10 years after power off.