solar spd,solar surge protector,pv spd,pv surge
-
Type 1+ Type 2 DC SPD for PV Systems
-
Impulse currents Iimp/Itotal : 6.25/12.5 kA (10/350µs)
-
In: 20kA / Imax: 40kA
-
Pluggable
-
Remote signaling (option)
-
IEC 61643-31 / EN 61643-31 compliant
Surge Protective Devices (SPDs) provide protection against electrical surges and spikes, including those caused directly and indirectly by lightning. They can be utilized as complete devices or as components within electrical equipment.
Photovoltaic (PV) system converts solar energy into direct current electricity. PV system ranges from small, rooftop-mounted or building-integrated systems with capacities from a few to several tens of kilowatts, to large utility-scale power stations of hundreds of megawatts. The potential impact of lightning events increases with PV system size. At locations with frequent lightning, unprotected PV systems will suffer repeated and significant damages. This results in substantial repair and replacement costs, system downtime and loss of revenue. Properly installed surge protective devices (SPDs) will minimize the potential impact of lightning events.
Sensitive electrical equipments of PV system like AC/DC Inverter, monitoring devices and PV array must be protected by surge protective devices (SPD).
To determine the proper SPD module for the PV system and its installation, you must know:
1.the lightning round flash density;
2.the system's operating temperature;
3.the system's voltage;
4.the system's short circuit current rating;
5.the level of waveform that is to be protected against (indirect or direct lightning); and the nominal discharge current.
The SPD that is provided on the dc output must have a dc MCOV equal to or greater than the maximum photovoltaic system voltage of the panel.
THOR TRS3-C40 series Type 1+2 DC SPDs for PV solar system can be like Ucpv DC500V,600V,800V,1000V,1200V, and the max 1500v.
TRS3-C40 1000V
- Electrical Characteristics
Typ name
TRS3-C40 1000V
SPD type
T1+T2
Network
PV network 1000 Vdc
Max. PV operating voltage(Ucpv)
1000 Vdc
Follow current
None
Nominal discharge current(In)
20kA
Max. discharge current(Imax)
40kA
Max. impulse discharge current (10/350μs) (Iimp)
6ka
Connection mode(s)
L+/L-/PE
Protection level +/PE (-/PE)(Up)
4.5 kV
Technology
MOV
Connection to Network
by screw terminals: 2.5-25 mm²
Format
Plug-in modular box
Mounting
Din rail 35 mm
Operating temperature
-40℃-- +70℃
Operating temperature
-40℃-- +70℃
Protection rating
IP20
Failsafe mode
Disconnection SPD of the PV line
Disconnection indicator
1 mechanical indicator by pole
Remote signaling
can be option if need
Dimensions
See diagram