ICP-6810 is a full-spectrum direct-reading inductively coupled plasma emission spectrometer for the determination oftrace and trace elements in different substances (dissolved in nitric acid,hydrochloric acid, hydrofluoric acid, etc.). It is widely used in environmentalprotection, petroleum products, rare earth, semiconductor, geology, metallurgy,chemical industry, clinical medicine, food, biological samples, criminalscience, agricultural research and other fields.
Performancecharacteristics
Performance stability
The use of all-solid-state rf power supply, with small size, high efficiency,stable output power, with a variety of protection functions and many otheradvantages, the load using fully automatic matching technology, matching speed,improve the efficiency of the use of power supply and the stability of theinstrument, and make the whole ignition process simple and convenient.
Injection automation
Adopting four-channel automatic design, the rotational speed can be set upaccording to the test demand to adjust the flow rate, carrier gas, plasma gas,auxiliary gas are all controlled by advanced mass flow controller, at the sametime can be equipped with imported high salt nebulizer, imported hydrofluoricnebulizer and so on to meet the customer's various test needs.
Precision analysis
The middle step grating prism cross dispersion mode is adopted, there is nomoving optical element, the ultra low stray light design is combined with theunique optical design, nitrogen distributed blowing, imported optical elements,intelligent and accurate automatic wavelength calibration algorithm.
Quick test
In American thermoelectric CID detector, the 160-1000nm range is continuouslycovered, and the intensity integral values of all analytical spectral lines areread out at one exposure to speed up the analysis.
Technicalparameters of the instrument
Output power: 800 -1500W
Total argon consumption:≤14L/min
Wavelength range:160nm - 1000 nm
Resolution: < 0.0065nm@200nm
Instrumenttechnical index
Method of observation: vertical observation
Liquid content:0.01ppm~thousands of ppm.
Solid content:0.001%~70%
Repeatability: RSD < 1%
Stability: RSD <1.5%(within 2 hours)
Element detection limit (μg/L): most elements 1ppb~10ppb
Applicationarea