Auxiliary Power Supply Three-phase Transformer
Applications:
Auxiliary power supply three-phase transformer is applied to output side of auxiliary inverter of subway and motor car. It plays the role of isolation and voltage transformation.
Features:
●Vacuum Pressure impregnation (V.P.I) is used to enhance insulation property;
●Silicon steel of high permeability is exploited, Low no-load losses, Small no-load current, less noise;
●Strong overload capacity, high compressive strength;
●Superior protection against humidity, can operate in high humidity environment;
●Small, light, convenient installation, and maintenances.
Technical Specifications:
●Rated Capacity: 5kVA~400kVA
●Rated Frequency: 50Hz
●Rated Voltage: 400V~700V
●Transformer Connection Section: Yy/Dy
●Impedance Voltage: 4%~8%
●Insulation Class: H
●Degree of Protection: IP04
●Cooling Method: Forced Air cooling/ Natural cooling
●Operating Mode: Continuous Duty