Rapidly COD analyzer for waste water testing
COD . Ammonia Nitrogen Dual Parameter Rapid Tester 5B-3C(V8)
1 >Product Introduction
Fully based on national regulations "Determination of water content of chemical oxygen demand rapid digestion spectrophotometry (HJ / T399-2007)" and "Determination of ammonia nitrogen in water quality Nessler reagent spectrophotometric method (HJ535-2009)" design and manufacture, applicable to many domestic and foreign testing standards.
Matching digester
2 >Functional characteristics
(01)Quick and accurate determination of chemical oxygen demand (COD) in surface water, reclaimed water, municipal wastewater and industrial wastewater. Concentration direct reading.(02)IT can determine Ammonia nitrogen, COD high range and COD low range water samples simultaneously and support both colorimetric cuvette and colorimetric tubes.
(03)The independent dual optical system has the advantages of direct reading, high accuracy, long service life and more stable.
(04)The 3.5 inch color LCD screen, humanized operation hint, simple to use.
(05)Self-calibration function of the instrument can be calculated and stored according to the standard sample, without manual production of curves.
(06)Large and small font display mode is free to switch, showing clearer data and more detailed parameters.
(07)It can transmit the current data and all stored historical data to the computer, and support USB transmission and infrared wireless transmission. (selecting)(08)Support both colorimetric cuvette and colorimetric tubes.
(09)The printer can print current data and all stored historical data.
(10)Equipped with professional consumables reagents, the working procedures are greatly reduced, the measurement is simpler and the results are more accurate.
(11)The instrument adopts the self-designed non-metal case. The machine is beautiful and generous.
(12)Support twelve thousand historical data storage (date, time, parameters, measurement results)
3>Technical Parameters
Mainframe | Item | COD high range | COD low range | Ammonia nitrogen |
Range | 20-10000mg/L(subsection) | 2-150mg/L(subsection) | 0.02-100mg/L(subsection) |
Measurement accuracy | COD<50mg/L,error≤±10%; COD>50mg/L,error≤±5% | Error≤±10% | Error≤±10% |
limits of detection | 0.1mg/L | 0.1mg/L | 0.1mg/L |
Determination time | 20min | 20min | 20min |
Batch processing | 16 | 16 | 20(can Scalable) |
Repeatability | ≤±5% |
Lamp life | 100 thousands hours |
Optical stability | ≤±0.005A/20min |
Anti-chlorine interference | <1000mg/L no influence ; <100000mg/L Optional |
Colorimetric method | Cuvette/Tube |
Data storage | 12000 |
Curve data | 180 |
Display mode | LCD(Resolution 320*240) |
Mainframe | Communication interface | USB /Infar-red (optional) |
Power supply | 220V |
Digestion instrument | Digestion temperature | 165℃±0.5℃ | 165℃±0.5℃ | —— |
Digestion time | 10/15min(optional) | 10/15min(optional) | —— |
Uniformity of Temperature Field | ≤2℃ | ≤2℃ | —— |
timer | 1min-96hour | 1min-96hour | —— |
Time switch | 3 | 3 | 3 |
Timing accuracy | 0.2 seconds/hour |
Power supply | AC220V±10%/50Hz |