HT-TA025 Trace Oxygen Transmitter

Model
Nature of the Manufacturer
Manufacturer
Product Category
Oxygen transmitter
Place of Origin
City, Province
Overview
HT-TA025 Trace Oxygen Transmitter
Product Details

    Measurement Principle: fuel cell

    Display Mode: LCD display with high resolution

    Measurement Range:0~10/100/1000PPm O2

    Measurement Accuracy: 0~1000PPm≤±1%FS

    0~100PPm≤±2%FS

    0~10PPm≤±3%FS

    Resolution: 0.1PPm

    Repeatability: ≤±1.0%FS

    Response Time: T90≤60S

    Output Port: 4-20mA.DC (Non-isolated output, load resistance<1KΩ)

    Communication Mode: RS485

    Power Supply: DC24V±10%, 200mA

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <99%RH, non-condensing

    Sample Gas Temperature: 0℃~40℃

    Sampling Mode: Free diffusion (other mode can be customized)

    Sample Gas Pressure: Relative pressure ±5kPa, stable pressure

    Background Gas: Inert, acid and reducing gas, etc.

    Sensor Service Life: >24 months (under normal conditions of use)

    Gas Circuit Port: NPT1/8 Internal Thread for protection and calibration cover

    Installation Method: KF40 flanged mounting

    a. The instrument has a small and nice look, a unique structure and design;

    b. The LCD display with high resolution is clear;

    c. The original imported fuel cell sensor has a high measurement accuracy, rapid response speed, long calibration cycle and strong anti-interference capability, etc.;

    d. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

    e. The menu lock function could prevent mis-operation, which may change instrument parameters and affect its performance;

    f. Automatic temperature compensation function could eliminate the impact of environmental temperature changes on the measurement accuracy;

    g. KF40 flanged mounting makes it easier to change the oxygen sensor.

    The instrument is special for glove box, but it can also be used for gas measurement of protection pipe under normal pressure.

    Measured gas pressure

    Background gas composition