HT-TA026 Trace Oxygen Transmitter

Model
Nature of the Manufacturer
Manufacturer
Product Category
Oxygen transmitter
Place of Origin
City, Province
Overview
HT-TA026 Trace Oxygen Transmitter
Product Details

    Measurement Principle: Ion current(limiting current)

    Display Mode: LCD display with high resolution

    Measurement Range:0~10/100/1000PPm O2

    Measurement Accuracy: 0~1000PPm≤±1%FS

    0~100PPm≤±2%FS

    0~10PPm≤±3%FS

    Resolution: 0.1PPm

    Repeatability: ≤±1.0%FS

    Response Time: T90≤15S

    Output Port: 4-20mA.DC (Non-isolated output, load resistance<1KΩ)

    Communication Mode: RS485

    Power Supply: DC24V±10%, 500mA

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <99%RH, non-condensing

    Sample Gas Temperature: 0~50℃

    Sampling Mode: Free diffusion (other mode can be customized)

    Sample Gas Pressure: Relative pressure ±5kPa, stable pressure

    Background Gas: N2 or other inert gas

    Sensor Service Life: >4 years (under normal conditions of use)

    Installation Method: KF40 flanged mounting

    a. The instrument has a small and nice look, a unique structure and design;

    b. The LCD display with high resolution is clear;

    c. The original imported ion current sensor consumes no service life when power is off, and it has a high measurement accuracy, rapid response speed and long calibration cycle, etc.

    d. The menu lock function could prevent mis-operation, which may change instrument parameters and affect its performance;

    e. Built-in automatic sensor protection could enter protection mode automatically when the sample gas concentration is too high;

    f. Automatic temperature and pressure compensation function could eliminate the impact of environmental temperature and pressure changes on the measurement accuracy;

    g. The instrument can measure trace oxygen in both nitrogen and argon;

    h. KF40 flanged mounting is easy to mount.

    The instrument is special for glove box, but it can also be used in online analysis of trace oxygen in mixed gas of oxygen, nitrogen and inert gas in air separation and protection gas furnace, etc.

    Measured gas pressure

    Background gas composition