HT-TA063 Oxygen Transmitter

Model
Nature of the Manufacturer
Manufacturer
Product Category
Oxygen transmitter
Place of Origin
City, Province
Overview
HT-TA063 Oxygen Transmitter
Product Details

    Measurement Principle: Zirconia

    Display Mode: 64×48 dot matrix OLED display

    Measurement Range (selectable): 0~10/100/1000PPm/1.00%/25.00% O2

    Measurement Accuracy: 0~1000PPm/1.00%/10.00% /25.00%≤±1%FS

    0~100PPm≤±2%FS

    0~10PPm≤±5%FS

    Resolution: 0.1PPm (trace)

    0.01% (normal)

    Repeatability: ≤±1.0%FS

    Response Time: T90<30S

    Output Port: 4-20mA.DC (Non-isolated output, load resistance<1KΩ)

    2 ways of programmable alarm output (Dry contact type, maximum load 220VAC/2A)

    Communication Mode: RS485

    Power Supply: DC24V±10%,1.5A

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <99%RH, non-condensing

    Sample Gas Temperature: 0℃~60℃

    Sampling Mode: Free diffusion

    Sample Gas Pressure: Relative pressure ±5kPa, stable pressure

    Background Gas: N2 or other inert gas

    Size: 110mm×99mm×45mm(H×W×D)

    Connecting Cable: 5 meters (standard)

    Sensor Service Life: >5 years (under normal conditions of use)

    Installation Method: Instrument: wall mounting

    Probe: plug-in (standard KF40 flange)

    a. The structure and design are compact, and the display is built in;

    b. Friendly communication menu allows an intuitive and convenient operation;

    c. The original imported zirconia sensor has a high measurement accuracy, rapid response speed and a long service life;

    d. Its wide measurement range could satisfy a full-range measurement of PPm~%;

    e. No calibration gas is needed and the instrument is not affected by the oxygen content in the operation environment;

    f. Automatic temperature compensation function could eliminate the impact of environmental temperature changes on the measurement accuracy;

    g. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

    h. Built-in standard RS485 communication port allows a unidirectional or bidirectional communication with computer or other digital communication equipment.

    It can be used in the oxygen content measurement in mixed gas of oxygen, nitrogen and inert gas in air separation, protection gas furnace, etc.

    Measurement range

    Measured gas pressure

    Background gas composition