HT-TA064 Oxygen Transmitter

Model
Nature of the Manufacturer
Manufacturer
Product Category
Oxygen transmitter
Place of Origin
City, Province
Overview
HT-TA064 Oxygen Transmitter
Product Details

    Measurement Principle: Fuel cell

    Display Mode: 64×48 dot matrix OLED display

    Measurement Range (selectable): 0~10/100/1000PPm/1.00%/10.00%/25.00% O2

    Measurement Accuracy: 0~1000PPm/1.00%/10.00%/25.00%≤±1%FS

    0~100PPm≤±2%FS

    0~10PPm≤±5%FS

    Resolution: 0.1PPm (trace)

    0.01% (normal)

    Repeatability: ≤±1.0%FS

    Response Time: T90<60S

    Output Port: 4-20mA.DC (Non-isolated output, load resistance<1KΩ)

    2 ways of programmable alarm output (Dry contact type, maximum load 220VAC/2A)

    Communication Mode: RS485

    Power Supply: DC24V±10%,200mA

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <99%RH, non-condensing

    Sample Gas Temperature: 0℃~60℃

    Sampling Mode: Free diffusion

    Sample Gas Pressure: Relative pressure ±5kPa, stable pressure

    Background Gas: N2 or other inert gas

    Size: 110mm×99mm×45mm(H×W×D)

    Connecting Cable: 5 meters (standard)

    Sensor Service Life: >48 months (under normal conditions of use)

    Installation Method: Instrument: wall mounting

    Probe: plug-in (standard KF40 flange)

    a. Friendly communication menu allows an intuitive and convenient operation;

    b. The original imported fuel cell sensor consumes no service life when power is off, and it has a high measurement accuracy, rapid response speed and long calibration cycle, etc.;

    c. No calibration gas is needed and the instrument is not affected by the oxygen content in the operation environment;

    d. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

    e. Built-in standard RS485 communication interface allows a unidirectional or bidirectional communication with computer or other digital communication equipment.

    f. Wall-mounting installation is easy and convenient to install and maintain.

    It can be used in the oxygen content measurement in mixed gas of oxygen, nitrogen and inert gas in air separation, protection gas furnace, etc.

    Measurement range

    Measured gas pressure

    Background gas composition