HT-LA413 Reflow Soldering Oxygen Analyzer

Model
Nature of the Manufacturer
Manufacturer
Product Category
Macrooxygen analyzer
Place of Origin
City, Province
Overview
HT-LA413 Reflow Soldering Oxygen Analyzer
Product Details

    Measurement Principle: Zirconia

    Display Mode: 128×64 dot matrix LCD

    Measurement Range: 0~10/100/1000PPm/1.00%/25.00% O2

    Measurement Accuracy: 0~1000PPm/1.00%/25.00%≤±1%FS

    0~100PPm≤±2%FS

    0~10PPm≤±5%FS

    Resolution: 1PPm

    Repeatability: ≤±1.0%FS

    Response Time: T90≤30S

    Output Port: 4-20mA (Non-isolated output, load resistance<1KΩ)

    0-10V.DC (Non-isolated output, load resistance>10KΩ)

    1 way of programmable alarm output (Dry contact type, maximum load 220V/2A)

    Communication Mode: RS232 (default) or RS485

    Power Supply: AC85~264V 50/60Hz

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <100%RH, non-condensing

    Sample Gas Temperature: 0℃~60℃

    Sampling Mode: Gas in or extraction sampling (please indicate sampling mode when ordering)

    Sample Gas Flow: 400~600mL/min

    Gas Inlet Pressure: Gas in: 5Kpa≤ relative pressure≤200Kpa (relief valve is recommended if the pressure >200Kpa)

    Extraction sampling: -10Kpa≤ relative pressure ≤5Kpa(please indicate the specific negative pressure value when ordering if the pressure<5Kpa since it will decide the gas circuit structure)

    Gas Outlet Pressure: Free venting (under safe conditions)

    Background Gas: N2 or other inert gas

    Size: 176mm×251mm×354mm (H×W×D)

    Hole-Cutting Size: 178mm×213mm(H×W) (in embedded mounting)

    Sensor Service Life: >5 years (under normal conditions of use)

    Gas Circuit Port: NPT 1/8 internal thread

    Instrument Weight: Net weight 4.5Kg

    Installation Method: Embedded mounting / counter mounting

    a. Friendly communication menu allows an intuitive and convenient operation;

    b. The original imported zirconia sensor has a high measurement accuracy, rapid response speed and long calibration cycle, etc.;

    c. It could operate in air for a long time without shortening sensor’s service life;

    d. The response speed is rapid and it could measure 1 PPm at minimum;

    e. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

    f. Automatic temperature compensation function could reduce the impact of environmental temperature changes on the measurement accuracy;

    g. No calibration gas is needed and the instrument is not affected by the oxygen concentration of operation environment;

    h. Original imported sampling pump (extraction sampling) is built in and has a long service life and stable performance;

    i. RS232 (default) or RS485 digital communication port can be selected according to clients’ requirement, to realize unidirectional or bidirectional communication with computer or other digital communication facilities.

    It is widely applied in the online oxygen analysis in protection gas of wave soldering, reflow soldering, soldering oven in electric or semi-conductor industry and inert gas sintering furnace, etc.

    Measurement range

    Measured gas pressure

    Background gas composition