HT-LA435 Split-Type Oxygen Analyzer

Model
Nature of the Manufacturer
Manufacturer
Product Category
Macrooxygen analyzer
Place of Origin
City, Province
Overview
HT-LA435 Split-Type Oxygen Analyzer
Product Details

    Measurement Principle: Zirconia

    Display Mode: 128×64 dot matrix LCD

    Measurement Range: 0~10/100/1000PPm/1.00%/25.00% O2

    Measurement Accuracy: 0~1000PPm/1.00%/25.00%≤±1%FS

    0~100PPm≤±2%FS

    0~10PPm≤±5%FS

    Resolution: 0.1PPm (trace)

    0.01% (normal)

    Repeatability: ≤±1.0%FS

    Response Time: T90<30S

    Output Port: 4-20mA (Non-isolated output, load resistance<1KΩ)

    0-10V.DC (Non-isolated output, load resistance>10KΩ)

    1 way of programmable alarm output (Dry contact type, maximum load 220V/2A)

    Communication Mode: RS232 (default) or RS485

    Power Supply: AC85~265V 50/60Hz, power dissipation<20VA

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <100%RH, non-condensing

    Sample Gas Temperature: 0℃~60℃

    Sampling Mode: Free diffusion

    Background Gas: N2 or other mixed gas of inert gas

    Size: Instrument: 155mm×155mm×118mm (H×W×D)

    Hole-Cutting Size: Instrument: 135mm×135mm (H×W)

    Sensor Service Life: >5 years (under normal conditions of use)

    Installation Method: Instrument: Embedded mounting

    Probe: Plug-in (KF40 flange mounting)

    a. Menu can be switched between Chinese and English and the operation is intuitive and convenient;

    b. Dot-matrix liquid crystal display with big screen makes it possible to display parameters of oxygen content, date, time, etc.;

    c. The original imported zirconia sensor consumes no service life when the power is off, and has a high measurement accuracy, rapid response speed and small zero drift value, etc.;

    d. Automatic temperature and pressure compensation could reduce the impact of environment temperature and pressure changes on the measured accuracy;

    e. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

    f. Factory default settings can be restored, preventing analyzer parameters setting chaos resulted by mis-operation;

    g. 5000 pieces of historical data can be stored automatically, enabling user to read historical data freely;

    h. Upper and lower alarm limit can be set among the full range;

    i. RS232 (default) or RS485 digital communication port can be selected according to clients’ requirement, to realize unidirectional or bidirectional communication with computer or other digital communication facilities.

                            