Transformer Turns Ratio Tester

Model
Nature of the Manufacturer
Manufacturer
Product Category
Transformer Tester
Place of Origin
City, Province
Overview
Function: single-phase/three-phase testTest range: transformation ratio 0.9~10000, angle 0-360°Measurement accuracy: ±0.1%+2 digits ( 0.9-500 ) ±0.2%+2 words ( 501-2000 ) ±0.5%+2 characters ( 2001-10000 )Resolution: minimum 0.0001Output voltage: automatically adjust according to the loadWorking power supply: AC220V±10% 50±1HzAmbient temperature: -10℃~40℃Relative humidity: ≤85%, no condensationDimensions: host: 360*290*170(mm) Wire box: 360*290......
Product Details

The turns ratio or voltage ratio test of the running transformer can check the correctness of the turns ratio of the transformer, the condition of the tap changer, whether the transformer is short-circuited between turns, and whether the transformer can operate in parallel. The XHBB128B Transformer turns ratio tester overcomes the shortcomings of the traditional transformer ratio bridge test. The operation is simple and intuitive. It adopts a three-phase precision inverter power supply, and the test is fast and accurate. It can test both single-phase and three-phase simultaneously.

 

For the three-phase transformation ratio test, the transformation ratio value, error, and tap position are automatically calculated. For the three-phase group test, the transformation ratio value, error, tap position, and group number are automatically calculated. In addition, it can also measure the angle between phases.


IMG_0533__


XHBB128B is suitable for a wide variety of transformers, especially for the measurement of Z-type transformers, rectifier transformers, ground transformers, electric furnace transformers, phase-shift transformers, balanced transformers, etc. It also has a very safe protection system, such as high and low voltage reverse protection, transformer turns Inter-short circuit protection, inadequate opening and closing protection of the tap changer, and full output short circuit protection greatly increase the stability of the instrument.


IMG_0528_


The transformer turns ratio tester has 7-inch high-definition color touch screen LCD, modular display, each operation step has English prompts, no manual, just look at the LCD prompts to complete the instrument operation. The instrument not only has print output, U disk interface, but also can be equipped with RS232 interface, which is convenient for paperless office.


4_



Technical parameter

1. Test range: 0.9~10000

2. Measurement accuracy: ±0.1%+2 words ( 0.9-500 )

±0.2%+2 words ( 501-2000 )

                        ±0.5%+2 characters ( 2001-10000 )

3. Resolution: minimum 0.0001

4. Output voltage: automatically adjust according to the load

5. Working power supply: AC220V±10% 50±1Hz

6. Ambient temperature: -10℃~40℃

7. Relative humidity: ≤85%, no condensation

8. Dimensions; host: 360*290*170(mm) Wire box: 360*290*170(mm)

9. Weight: Mainframe 5.9KG Line box: 5.65KG



Panel description

image


(1) Display screen: 7-inch high-definition color touch screen LCD, digital adjustment backlight, display operation menu and test results.

(2) High voltage terminal: connect the yellow, green, red and black terminals of the test line, and connect the three phases a, B, C and O on the high voltage side of the tested transformer.

(3) Low voltage terminal: yellow, green, red and black are connected to three phases a, B, C and o at the low voltage side of the tested transformer

(4) AC220V: power input port of the whole machine, connected to AC220V power frequency power supply.

(5) Protective grounding post.

(6) Communication: serial communication

(7) USB: USB storage

(8) Printer: print test results after measurement.

 

 


Precautions

(1) For transformers with multiple tapping points, the input of equal tapping level, tapping type and rated high and low voltage values is to enable the test results to automatically calculate the error value and the tapping position of the tap changer. Once the rated data is input, When testing each tapping point, it can automatically calculate the error value of the point and which tapping point the point is (i.e. what tapping position is), and there is no need to change the data.

 

(2) Equal tapping stage, also known as tapping distance, with voltage combination of 110 ± 8 × 1.25% / 10.0 transformer, 1.25% is equal tap level.

 

(3) Tapping type, voltage combination 110 ± 8 × For 1.25% / 10.0 transformers, the equal tapping level is 8 + 1, i.e. 9, that is, the rated tapping position can be input. In this way, for transformers whose rated tapping position is not in the middle point, there will be no error in the measurement of tapping position.

 

(4) Transformation ratio: when three-phase electricity is applied to the test object, the measured voltage ratio relationship between high voltage and low voltage, and the turn ratio is the ratio relationship between the number of turns of high voltage and low voltage windings. For transformers with star connection for high voltage (with or without neutral point) and triangular connection for low voltage, the transformation ratio is √ 3 times of the turn ratio. For transformers with star connection for low voltage (with or without neutral point) and triangle connection for high voltage, the turn ratio is √ 3 times of the change ratio.

 

(5) For transformer with neutral point, such as transformer with yn-d-11, there is deviation between measurement according to yn-d-11 and measurement according to y-d-11, and theoretical analysis according to y-d-11 is better.

 

(6) For the transformer with 19 gears of on load tap changer, if the tapping of 9, 10 and 11 are the same value, enter 9 when the instrument inputs the tapping type.

 

(7) The transformer with tap changer on the low-voltage side shows that the tap position and the actual tap position are inverted.

 

(8) For transformers with low voltage level, when the effective digits of the input voltage value are not enough, the high and low voltage can be input after multiplying the constant of 10 or 100 at the same time.

 

(9) When testing single-phase transformer, just select "single" as the measurement option.



Packing List

Serial number

 Name

 Quantity

1

Transformation ratio tester

 1 set

2

power cord

 1 piece

3

Test line

 1 set

4

Serial port line

 1 piece

5

ground wire

 1 piece

6

Printing paper

 Volume 1

7

Fuse tube (1a)

 2



Onsite testing

-2


-3





Remarks

◆This pointing device has passed the international standard certification CE ISO

◆The general delivery time of the equipment is 5-8 days. The specific negotiation at the time of ordering shall prevail.

◆The standard packaging is a wooden box for export to protect the safety of equipment transportation.

◆Usually shipped by international express, such as FEDEX, DHL, , ARAMEX, etc. It can be negotiated according to different countries.


XZH TEST welcomes your inquiry


FAQ


Q:  What’s your terms of payment?

A:  Payment≤USD2000, 99% paid in advance. Amount over USD2000, can be negotiated.

Q: How long is your warranty?

A: We offer one year of warranty.

Q:  Why should you buy the Transformer turns ratio tester from us?

A:  Professional R&D and technical support, accept OEM, ODM orders;

      Provide overall laboratory solutions to your project.

     Strict quality control and one year of warranty.

     Short lead time and fast delivery.

     Quick response to your any inquiries.




Similar Product Recommend