Single-jet, Wet dial.sizes Ø15mm, Available for cold water (50°C)Material of body: Brass. Surface is powder coatingMeasuring accuracy conform to ISO 4064 class B Standard
MAIN TECHNICAL DATA
Meter size Dia DN (mm) | Class | qs Overload Flow | qs Nominal Flow
| qs Transitional Flow | Qmin Min Flow | Min Reading Lectura | Max Reading Lectura |
| m3/h | 1/h | m3 |
| 13 | B | 3 | 1.5 | 120 | 30 | 0.0001 | 99999 |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
Meter size Dia DN (mm) | Length(L) | Width(B) | Height(H) | Connecting Thread D | Weight Kg |
| mm |
| 13 | 110 | 84 | 82 | G 3/4B | 0.83 |
WORKING CONDITION
Water temperature:≤50℃ for cold water meter
Water temperature:≤90℃ for hot water meter
Working pressure:≤1.6Mpa