Multi-jet, Dry-dial, vertical typeIron body or Brass body for option.Available for cold water (30°C) and hot water (90°C), sizes Ø 15 to 25 mm (½" – 1").Installed in vertical pipeline and is suitable for household as branch meterConform to ISO4064 standard
MAIN TECHNICAL DATA
Meter size Dia DN (mm) | Class | qs Overload Flow | qs Nominal Flow
| qs Transitional Flow | Qmin Min Flow | Min Reading Lectura | Max Reading Lectura |
| m3/h | 1/h | m3 |
| 15 | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
| B | 120 | 30 |
| 20 | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
| B | 200 | 50 |
| 25 | A | 7 | 3.5 | 350 | 140 | 0.0001 | 99999 |
| B | 280 | 70 |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
DIMENSIONS AND WEIGHT
Meter size Dia DN (mm) | Length | Width | Height
| Connrcting Thread D | Weight Kg |
| mm |
| 15 | 95 | 135 | 120 | G3/4B | 1.5 |
| 20 | 99 | 150 | 130 | G 1B | 1.7 |
| 25 | 110 | 160 | 130 | G1 1/4 B | 3 |
WORKING CONDITION
Water temperature:≤50℃ for cold water meter
Water temperature:≤90℃ for hot water meter
Working pressure:≤1.0Mpa