- Apply to Electric/Hybrid Vehicle Isolation Measurement;
According to FMVSS305 and ECE R94;- All channel isolation voltage>1500V;
- High Voltage measurement range ±1000V;
- Built-in adaptive excitation power 70V~950V;
- Battery inside and 4 hours support;
- Data Logger with 10HZ,max recording 5 hours;
- All parameters can be configurable, and MME data format supplied.
RES-1000A is used for EV/HV Isolation test including crash test. It includes voltage (Vb, V1 and V2) and Isolation Resistance measurement before and after T0. And Energy TE measurement can be also enabled. The whole measurement process is finished automatically. And the result will be shown by LED. The original data can be download by operation software. After external battery disconnect, an internal high voltage module of RES-1000A can supply the same voltage of Vb, in order to measure isolation resistance automatically after T0. Additionally, 4 channels Temperature sensors input are supported. Together with others channels, all data can be recorded with 10Hz sampling, and download with ISOMME format after test.
Specification (25℃)
| Name | Unit | Value |
| Voltage Range | V | ±1000 |
| Iso. Res. Range | Ω/V | 9800 |
| TE Range | J | >10 |
| HV Supply | V | 70-800 |
| Trigger Input | Switch or RS485 | |
| Temp. Input | 4 channels PT1000 | |
| Power Supply | V | 9-18 |
| Working Temp | ℃ | -10-45 |
| Case Materials | / | 尼龙 |
| Sampling Fre. | Hz | 10 |
| Memory Time | h | 5 |
| Battery Time | inside, support 5h | |
| Comm. Type | Ethernet | |
| Display | 3 * 4-bit LED | |
| Bus Connector | LEMO EGG.1B.308 | |
| Trigger Conn. | LEMO EGG.1B.305 | |
| Alarm Output | LEMO EGG.0B.305 | |
| Temp. Input | LEMO EGG.0B.304 | |
| Voltage Input | 2mm banana connector*3 | |
| Isolation Voltage | 1500VDC | |
| Trigger Signal | Switch and RS485 | |
| Voltage Alarm | Yellow LED | |
| Res. Alarm | Red LED and Speaker | |
| TE Alarm | Red LED | |
| Memory and Battery Time Left | LED display | |
| Mounting | M4 Screw | |
| Size | 182mm×86mm×73mm | |
| Weight | 550g | |
Attach 1. Interface CommentVoltage Input(2mm banana):
Red:Voltage (BAT)+;
Blue:Chassis;
Black:Voltage (BAT)-
BUS Connector(LEMO EGG.1B.308):LEMO EGG.1B.308—Pin1—15V+
LEMO EGG.1B.308—Pin2—15V+
LEMO EGG.1B.308—Pin3—15V-
LEMO EGG.1B.308—Pin8—15V-
LEMO EGG.1B.308—Pin4—TX+
LEMO EGG.1B.308—Pin5—TX-
LEMO EGG.1B.308—Pin6—RX+
LEMO EGG.1B.308—Pin7—RX-
Trigger Input(LEMO EGG.1B.305)LEMO EGG.1B.305—Pin1—Trigger sw+
LEMO EGG.1B.305—Pin2—Trigger sw-
LEMO EGG.1B.305—Pin3—NA
LEMO EGG.1B.305—Pin4—RS485+
LEMO EGG.1B.305—Pin5—RS485
Control ButtonsON/OFF: Power on and power off
RESET: Clear memory
START/STOP: Measurement start and stop
Status LEDRDY: Device is ready and operational;
MEAS: Measuring and Recording;
DATA: data available;
T0:T0 indicator;
ETH: Communication;
Charging: Battery Charging;BAT:Battery Discharging。
Number LED:Voltage, Isolation Resistance, TE, Memory and Battery Left display.
Note: All test parameters can be set and the data with ISOMME format can be download by software.