- Applied to ignition tests of airbag, seatbelt and other initiators;
Max. configuration of 4 independent channels;- Squib current 1.00A~3.00A adjustable;
- Squib pulse width 0.1ms~5ms adjustable;
- Squib delay 0.0ms~1000.0ms adjustable;
- Airbag resistance measure automatically;
- Multi-channels I/O and sensor connecting channels supported, easy to realize airbag squib test system building.
AT-4S is mainly used in the ignition test of airbags, seat belts and engine hood lifters. The ignition device is equipped with trigger input, and multi-channel trigger output can be used to trigger high-speed cameras, data acquisition equipment, etc.; equipped with multi-channel IO, can be used for logic control such as lighting, ventilation, access control, etc.; equipped with multi-channel analog input, Sensor signals such as pressure, acceleration and force can be collected synchronously.
Specification (25℃)
| Name | Unit | Value |
| Squib channel | Channels | 1~4 |
| Squib current | A | 1.00~3.00 |
| Pulse width | ms | 0.1ms~5.0ms |
| Delay | ms | 0.0~1000.0 |
| Current sampling | Hz | 10000 |
| Voltage sampling | Hz | 10000 |
| Trigger input | T0 | Switch+TTL |
| Trigger output | default switch | 6 channels |
| Digital output | default switch | 8 channels |
| Digital input | default switch | 8 channels |
| Analog input | sensor input | 8 chs (10kHz) |
| Res. measure | Ohm | 1.000~5.000 |
| Squib voltage | V | >18V |
| Communication | / | Ethernet |
| Power button | Self-Lock | Button & LED |
| Power supply | With fuse | 220VAC |
| LED indicators | POW, SAFETY, ARM, T0 | |
Interface define:


Squib OUT1-2:LEMO EGG.1B.305

| Pin 1 | Fire+ |
| Pin 2 | Sense+ |
| Pin 3 | Fire- |
| Pin 4 | Sense- |
| Pin 5 | Not Connect |
![]() | Airbag Stationary Squib Device AT-4S-EN |
,